Installation Guide

9
8 ELECTRICAL CONNECTION TO JUNCTION BOX
9 SECURE THE OVEN TO THE CABINETRY
1 Position the oven in the prepared cavity.
IMPORTANT!
Do not lift the oven by the door handle.
2 Use the supplied screws and spacers to secure the oven
to the cabinetry.
Double oven models only:
There are 4 screws and spacers provided (two per side).
IMPORTANT!
Do not over-tighten the screws.
Take care not to damage the lower trim of the oven.
Do not seal the oven into the cabinetry with silicone or glue.
This makes future servicing difficult. Fisher & Paykel will not
cover the costs of removing the oven, or of damage caused by
this removal.
Ensure supplied
spacer is fitted
between oven and
cabinetry
Junction box
location for:
undercounter
installation
Junction box
location for:
wall installation
WOSV330 Single
Voltage Max. current draw Max. load
208V 16.6A 3.5kW
240V 19.4A 4.6kW
WODV330 Double
Voltage Max. current draw Max. load
208V 33.2A 7.0kW
240V 38.3A 9.2kW
1 Disconnect the power supply.
2 Remove the junction box cover.
3 Connect the oven cable to the
junction box through the U.L.
– listed conduit connector.
4 Connect the two black wires
together with twist-on connectors.
5 Connect the two red wires
together with twist-on connectors.
6 Connect electrical connection
according to local codes and
ordinances.
If local codes permit connecting the
cabinet-grounding conductor to the
neutral white wire in the junction box:
7A Connect the factory-taped green and
white oven cable wires to the neutral
(white) wire in the junction box.
8A Replace the junction box cover.
OR If local codes DO NOT PERMIT
connecting the cabinet-grounding
conductor to the neutral (white)
wire in junction box:
7B Separate the factory-taped green
and white oven cable wires.
8B Connect the white oven cable wire to
the neutral (white) wire in junction box.
9B Connect the green grounding oven
cable wire to a grounded wire in the
junction box.
!0B Replace the junction box cover.
OR If connecting to a four-wire
electrical system:
7C Separate the green and white oven
cable wires.
8C Connect the white oven cable wire to
the neutral (white) wire in junction box.
9C Connect the green grounding oven cable
wire to the (green) grounding wire in
the junction box.
Do not connect the green grounding wire
to the neutral (white) wire in junction box.
!0C Replace the junction box cover.
Nameplate
Cable from
power supply
Black
wires
UL – listed
conduit connector
Box
Red
wires
White and green
grounding oven wires
– factory taped
UL – listed
conduit connector
Box
Cable from
power supply
White
wires
Red
wires
Green grounding
oven wires
– factory taped
Black
wires