INSTALLATION INSTRUCTIONS
WARNING!
Electrical wiring must be done by qualified person(s) in accordance with
all applicable codes and standards and the unit must be grounded.
5
Electrical connection
●
Run three wires, two for the power supply and one for the ground wire, from the
power connection box on the ventilation hood to a power connection point near
the installation.
●
Open the power connection box on the ventilation hood and secure the power
conductor with a cULus listed strain relief (not included).
●
Connect the power conductors to the conductors for the ventilation hood,
black to black and white to white.
●
Connect the grounding wire (green or bare) to the ground conductor (green)
of the ventilation hood power connection box.
●
Secure all the connections with cULus listed wire nuts.
●
Replace the power connection box cover.
M
Switch
Interrupteur
Brown/Marron
Gray/Gris
Black/Noir
Red/Rouge
Blue/Bleu
Purple/Violet
White/Blanc
Yellow/Green
Jaune/Vert
White/Blanc
Yellow/Green Jaune/VertGround
Brown/Marron Motor
Gray/Gris
Black/Noir
Red/Rouge
Blue/Bleu
Black/Noir
White/Blanc
Black/Noir (L)
White/Blanc (N)
Green/Vert (E)
Black/Noir
Black/Noir
White/Blanc Motor
Orange/Orange Motor
Capacitor
Bornier
Junction
Box
Green/Vert
120V~60Hz
Gray 4 speed
Black 3 speed
Red 2 speed
Blue 1 speed
Brown (neutral)
Lamp/Lampes