INSTALLATION INSTRUCTIONS USER GUIDE Chimney Pyramid Rangehood HC60PHTX1, HC90PHTX1 and HC120PHTX1 models NZ AU IN ROW
CONTENTS Introduction 3 Safety and warnings 4 Installation instructions 6 Operating instructions 15 Cleaning and maintenance 16 Parts and accessories 17 Manufacturer’s Warranty 18 Customer Care IMPORTANT! SAVE THESE INSTRUCTIONS The models shown in this user guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website www.fisherpaykel.
INTRODUCTION Thank you for purchasing a Fisher & Paykel product. Thousands of hours go into the design, engineering, testing and perfecting of each Fisher & Paykel appliance. The care and attention given to creating these beautiful products doesn’t stop once it has found its home with you.
SAFETY AND WARNINGS ! 14 kg WARNING! Weight Hazard The appliance is heavy. Please ensure adequate care is taken when installing the appliance to prevent personal injury. The appliance must be installed onto a solid wall, stud, beam or truss. Weight of the products are 14 kg (HC60) / 16 kg (HC90) / 19 kg (HC120). (HC60) 16 kg (HC90) 19 kg (HC120) ! WARNING! Electric Shock Hazard Always disconnect the appliance from the mains power supply before carrying out any maintenance or repairs.
SAFETY AND WARNINGS ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● ●● Exhaust air must not be discharged into an existing flue that is used for exhausting fumes from appliances burning gas or other fuels. There shall be adequate ventilation of the room when the rangehood is used at the same time as appliances burning gas or other fuels.
INSTALLATION INSTRUCTIONS Contents of packaging INSTALLATION INSTRUCTIONS USER GUIDE Chimney Pyramid Rangehood HC60PHTX1, HC90PHTX1 and HC120PHTX1 models NZ AU IN ROW Rangehood hood (1) Installation instructions User guide manual (1) Chimney (1) Upper chimney (1) Upper chimney bracket (1) Chimney bracket (1) 150 mm diameter ducting adapter (1) Expansion plug (10) 30 mm self-tapping screw (10) 10 mm self-tapping screw (4) 6
INSTALLATION INSTRUCTIONS Product dimensions Ø I H Power cord location G C F E A max A min D B J K min 380 mm J J K max HC60PHTX1 HC90PHTX1 HC120PHTX1 655 – 1094 655 – 1094 655 – 1094 Overall width of product 598 898 1198 Overall depth of product 500 PRODUCT DIMENSIONS A B C D E F G Overall height of product Distance from centre of ducting outlet to back of product H Distance from centre of ducting outlet to side of chimney I J Diameter of ducting outlet K Distance
INSTALLATION INSTRUCTIONS Height of rangehood L M INSTALLATION DIMENSIONS L Installation height Ducted Recirculation M Height top of cooktop to base of product mm min. 680 – max. 1094 min. 720 – max. 1094 min. 660 – max. 750 Rangehood installation height above the cooktop is the user’s preference. Lower installation heights will improve the efficiency of capturing cooking odours, grease, and smoke.
INSTALLATION INSTRUCTIONS Venting options Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air are fulfilled. The rangehood can be installed to operate with the exhaust air ducted externally from the kitchen, or installed to operate with the exhaust air recirculating within the kitchen. Ducted For ducted installation it is recommended that 150 mm diameter, rigid or semi-rigid ducting is used.
INSTALLATION INSTRUCTIONS Installation WARNING! ●● ●● ●● This appliance is heavy and requires two persons for unpacking and installation Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards. IMPORTANT! Wear gloves to protect against sharp edges.
INSTALLATION INSTRUCTIONS U T Upper chimney bracket attachment point R P Chimney bracket attachment point Upper rangehood attachment point S Lower rangehood attachment point Q O N Fig.
INSTALLATION INSTRUCTIONS Fig.3 3 Attach the ducting adapter to the rangehood ●● 12 Place the ducting adapter onto the rangehood and screw it in place using 10 mm screws.
INSTALLATION INSTRUCTIONS 4 Wall mounting ●● Remove the filters – pull the relative catch and tilt the filter downwards until it disengages from the supports. ●● ●● ●● Hang the rangehood off the upper rangehood mounting screws with 2 mm gap. Hang off the keyhole attachment points on the back of the rangehood then tighten the screws. Attach the lower rangehood mounting screws to fix the rangehood to the wall. Refit the filters.
INSTALLATION INSTRUCTIONS 5 Attach the ducting ●● Attach ducting to the ducting adapter using aluminium duct tape and vent outside. 6 Attach chimney ●● ●● ●● Bend the tabs on the chimney (A). Place chimney around the rangehood chassis and hang off the chimney bracket (B). Extend the upper chimney and attach to the upper chimney bracket with 10 mm screws (C). A 7 Remove packaging ●● 14 B Remove all packaging and protective wrappings.
OPERATING INSTRUCTIONS Control panel CONTROL PANEL FEATURES Light Turns the light on and off. Power ON/OFF Turn the rangehood on or off. The fan automatically turns on to operate at level 1. Reduce fan speed Adjust the fan speed levels from 1 – 3 with 1 being the lowest. Fan speed indicator The fan speed level icon illuminates red with the current fan speed Increase fan speed Adjust the fan speed levels from 1 – 3 with 3 being the highest. Max Turn the fan directly onto the maximum fan speed.
CLEANING AND MAINTENANCE WARNING! Unplug or disconnect the appliance from the power supply before servicing or cleaning. IMPORTANT! ●● ●● Never use abrasive or oil based cleaners. Wear gloves to protect against sharp edges. Maintenance The rangehood should be cleaned regularly using a mild, liquid detergent and a clean soft cloth to avoid a build-up of grease occurring. Avoid the use of corrosive chemicals, abrasive cleaning products, hard brushes and steel wool pads.
PARTS AND ACCESSORIES ITEM REFERENCE NUMBER Aluminium filter 792564 Recirculation carbon filter x2 792481 Recirculation diverter 792560 Ducting kit 150 mm (eaves) PD-RHK150E Ducting kit 150 mm (wall) PD-RHK150W 17
MANUFACTURER’S WARRANTY You automatically receive a 2 year Manufacturer’s Warranty with the purchase of this rangehood covering parts and labour for servicing within the country of purchase. Fisher & Paykel undertakes to: Repair or, at its option, replace without cost to the owner either for material or labour any part of the product, the serial number of which appears on the product, which is found to be defective within TWO YEARS of the date of purchase.
MANUFACTURER’S WARRANTY For Australian Customers This Manufacturer’s Warranty is an extra benefit and does not affect your legal rights. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage.
CUSTOMER CARE Before you call for service or assistance... Check the things you can do yourself. Refer to the installation instructions and your user guide and check that: 1 Your product is correctly installed. 2 You are familiar with its normal operation. If after checking these points you still need assistance or parts, please refer to your nearest Fisher & Paykel trained and supported service technician, Customer Care, or contact us through our website www.fisherpaykel.com.
CUSTOMER CARE *If you call, write or contact us via our website please provide: your name and address, model number, serial number, date of purchase and a complete description of the problem. This information is needed in order to better respond to your request for assistance. Product details can be found under the aluminium filter. Registration Register your product with us so we can provide you with the best service possible. To register your product visit our website: www.fisherpaykel.
www.fisherpaykel.com Copyright © Fisher & Paykel 2016. All rights reserved. The product specifications in this booklet apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time. You should therefore check with your dealer to ensure this booklet correctly describes the product currently available. NZ AU IN ROW 104043 A 02.