installation guide

22
INSTALLATION INSTRUCTIONS
Electrical connection
WARNING!
Electrical wiring must be done by qualified person(s) in accordance with all
applicablecodes and standards and the unit must be grounded.
Turn off electricity at the service panel before wiring the unit.
A 120 volt, 60Hz AC-only electrical supply is required on a dedicated 20A branch
circuit. A time-delay fuse or circuit breaker is recommended.
Use only with range hood cord-connection kits that have been investigated
andfoundacceptable for use with this model range hood.
Range hood internal blower electrical connection (HCB30/36/48 models only)
1
Connect the plug present inside the range hood to the internal blower.
2
Remove the junction box cover as shown below.
3
Remove knockouts as required and install a cULus listed 3/4” (19mm)
wiring conduit andconduit connector or strain relief in the junction box.
4
Run three wires for the power supply through the 3/4” (19mm) strain relief or
conduit from the power supply to junction box. Tighten the strain relief.
5
Connect the power supply wires to the range hood wires in the following
order using cULus listed wire nuts:
black to black wire
white to white wire
green/yellow wire to green wire.
6
Close the range hood junction box cover.
Complete the installation
1
Remove all protective wrapping from range hood.
2
Install the filters and grease trays as described in the ‘Cleaning and maintenance’ section.
3
Turn the power on at the control panel.
4
Check the operation of the range hood as described in the ‘Operating instructions’ section.
Power supply conduit
From control panel