INTEGRATED RANGE HOOD HPB3011-4, HPB3011-6, HPB3019-6, HPB3611-6, HPB3619-6, HPB3619-12, HPB4819-12, HP3019 (shell), HP3619 (shell) & HP4819 (shell) models INSTALLATION GUIDE US CA 105305A 06.
1 SAFETY AND WARNINGS ! 2 FP Pro Hood Fasteners WARNING! Weight Hazard ●● ●● ¾” OD x 3/16” ID Flat Washer #10-32 Pan Head Pozi Drive Wall Plug The appliance is heavy. Please ensure adequate care is taken when installing the appliance to prevent personal injury. Please read this manual carefully, and keep it after installation for future reference. Keep all packing materials (box, pallet, straps) until the unit has been inspected. Inspect the product to check there is no shipping damage.
3 PRODUCT AND CABINETRY CUT-OUT DIMENSIONS HP3019, HP3619 and HP4819 models HPB3011-4, HPB3011-6, HPB3019-6, HPB3611-6, HPB3619-6, HPB3619-12 and HPB4819-12 models c C R D S S D L R M H M G G H K A J I N B O c P E J F D All models P 1 1/2” (38mm) U D T Refer to page 4 for details on ‘Cabinet mounting installation’ 2 F A Q B c I E
3 PRODUCT DIMENSIONS PRODUCT AND CABINETRY CUT-OUT DIMENSIONS HPB3011-4 HPB3011-6 HPB3019-6 HPB3611-6 HPB3619-6 HPB3619-12 HPB4819-12 HP3019 HP3619 HP4819 inches (mm) inches (mm) inches (mm) inches (mm) inches (mm) inches (mm) inches (mm) inches (mm) inches (mm) 18 3/16” (462) 18 3/16” (462) 18 3/16” (462) 18 3/16” (462) 18 3/16” (462) 18 3/16” (462) 6 3/4” (172) 6 3/4” (172) 6 3/4” (172) 15” (381) 15” (381) 15” (381) 15” (381) 15” (381) 15” (381) 5 9/16” (142) 5 9/16” (1
4 INSTALLATION PREPARATION IMPORTANT Range hood height The HPB3011-4, HPB3011-6 and HPB3611-6 models are not suitable for use with a high powered professional style cooktops. A Range hood width ●● ●● ●● INSTALLATION DIMENSIONS The range hood width is recommended to be no less than the width of the cooktop. A wider range hood can be used to increase the capture area if space is not restricted. The range hood should ideally be centered above the cooktop for proper performance.
4 ●● ●● INSTALLATION PREPARATION Electrical requirements Venting requirements WARNING! IMPORTANT! To reduce risk of fire and to properly exhaust air, be sure to duct air outside — Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. Electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards. This unit must be grounded/earthed.
5 INSTALLATION INSTRUCTIONS Recirculation kit — carbon filter (not included) An optional recirculation kit can be ordered separately and mounted into your range hood, see ‘Parts and accessories’ section of your User guide and visit fisherpaykel.com to order. WARNING! ●● ●● IMPORTANT! Venting directly into the cabinet with no vent is not permitted. WARNING! ●● ●● ●● ●● This appliance is heavy and requires two persons for unpacking and installation.
5 INSTALLATION INSTRUCTIONS D C E Note: The range hood must be installed with the control panel on the right.
6 FIELD WIRING COMPARTMENT 8 WIRING DIAGRAM
FISHERPAYKEL.COM © Fisher & Paykel Appliances 2018. All rights reserved. The product specifications in this booklet apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time. You should therefore check with your Dealer to ensure this booklet correctly describes the product currently available. US CA 105305A 06.