Installation Guide
Table Of Contents
16 | COFFEE MAKER INSTALLATION GUIDE
Verify the minimum measurements required for correct installation of the appliance. The coffee maker must be
installed in a column and the column must be firmly fixed to the wall with commercially available brackets.
IMPORTANT!
●
All installation or maintenance operations must be performed with the appliance disconnected
from the mains electricity supply.
●
Kitchen furniture in direct contact with the appliance must be heat resistant 149°F min (65°C min).
●
To guarantee correct ventilation, leave a gap at the bottom of the cabinet
(see measurements below).
6A CABINETRY DIMENSIONS (18 1/8" (460mm) HIGH CAVITY)
PROUD INSTALL
FLUSH INSTALL
5/8–13/16"
(16–20mm)
min 1/16" (2mm)
5/8–13/16"
(16–20mm)
Electrical supply
CABINETRY DIMENSIONS
EB24 MODELS
inches (mm)
I
Minimum inside width of cavity 22 1/16" (560)
J
Overall width of cabinetry 23 5/8" (600)
K
Minimum inside height of cavity 17 3/4" (450)
L
Overall height of cabinetry 18 1/8" (460)
M
Minimum inside depth of cavity 21 7/16" (545)
n
Ventilation Air Gap 2" (50)
TOPSIDE
M
J
I
Lk
n
13/16"
(20mm)
13/16"
(20mm)