@0GAS CONVERSION
Adjusting the cooktop burner minimums
When switching from one type of gas to another, the minimum
flow rate must also be correct:
The flame should not go out even when passing suddenly from
maximum to minimum flame.
To regulate the flame follow these instructions:
Semi-rapid burner (A)
Light the burner
Set the gas valve to position (minimum rate)
Remove the dial.
With a thin screwdriver, turn the regulation screw inside the tap rod
until adjustment is correct
Inside crown of DUAL burner (B)
Light the dual burner
Set the gas valve to position (minimum rate of inner crown)
Remove the dial
With a thin screwdriver, turn the regulation screw until adjustment is correct.
The screw is accessible via a hole in the microswitch.
Outside crown of DUAL burner (C)
Light the dual burner
Set the gas valve to position
(minimum rate of outer crown and maximum rate of inner crown).
Remove the dial
With a thin screwdriver, turn the regulation screw inside the tap rod
until adjustment is correct
For LP/PROPANE gas, tighten the adjustmentacrews completely.
A Regulation screw (Triple-Ring and Semi-Rapid burner)
B Regulation screw (Inner crown of dual burner)
C Regulation screw (Outer crown of dual burner)
A
C
B
Regulation
screws
Regulation
screws
Regulation
screws