Installation Instructions

26
!9GAS CONVERSION (GAS GAS MODELS ONLY)
Adjusting the lower oven burner minimum
1 Turn on the burner by setting the oven dial the highest temperature setting.
2 Remove the dial and unscrew the by-pass screw (A) about three times by passing a small
flat screwdriver (Ø1/8” (3mm) blade, 3 15/16” (100mm) length) through the panel opening.
3 Re-mount the dial and let the oven heat up for about 10 minutes, then bring
the dial to the lowest temperature setting. to operate the thermostat by-pass.
4 Remove the dial again. Taking care not to turn the tap rod, slowly screw the by-pass screws
(A) until you obtain a flame of 1/8–5/32” (3–4mm) in height.
The flame should not go out even when passing suddenly from maximum to minimum
flame.
NOTE: For LP/PROPANE gas the by-pass screw must be fixed thoroughly.
A