Installation Guide

22
22
Fig. 2.14
R
1
R
3
R
2
SETTING THE BURNER MINIMUM OF THE COOKTOP BURNERS
When switching from one type of gas to another, the minimum ow rate must also be cor-
rect: the ame should not go out even when passing suddenly from maximum to minimum
ame.
To regulate the ame ( g. 2.14) follow the instructions below:
Triple-ring and semirapid burner
Light the burner.
Set the gas valve to
position (minimum rate).
Remove the knob.
With a thin screwdriver, turn the regulation screw “R
1
” until adjustment is correct.
Inside crown of DUAL burner
Light the DUAL burner.
Set the gas valve to
position (minimum rate of inner crown).
Remove the knob
With a thin screwdriver, turn the regulation screw “R
2
” until adjustment is correct.
Outside crown of DUAL burner
Light the DUAL burner.
Set the gas valve to
position (minimum rate of outer crown and maximum rate
of inner crown).
Remove the knob.
With a thin screwdriver, turn the regulation screw “R
3
” until adjustment is correct.
For LP/PROPANE gas, tighten the adjustment screws completely.
2
R
1
Regulation screw (Triple-ring and semirapid burner)
R
2
Regulation screw (Inner crown of dual burner)
R
3
Regulation screw (Outer crown of dual burner)