FREESTANDING RANGE OR90 Dual Fuel models INSTALLATION GUIDE NZ AU
1 SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS! WARNING! Electrical shock hazard Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains electricity supply. Connection to a good ground wiring system is absolutely essential and mandatory. Alterations to the domestic wiring system must only be made by a qualified electrician Failure to follow this advice may result in electrical shock or death.
2 GENERAL INSTALLATION INFORMATION ● ● ● ● ● ● ● ● ● Cleaning and servicing Replacement parts Service should only be performed by an authorised technician. When removing appliance for cleaning and/or service: Shut off gas at main supply. Disconnect AC power supply. Disconnect gas line to the inlet pipe. Carefully remove the range by pulling outward. CAUTION: Range is heavy; use care in handling.
3 PARTS SUPPLIED FOR INSTALLATION Anti-tip bracket and lock pin (1) Screws and plastic sleeve anchors (2) Pressure regulator (1) Test point adapter (1) brass conical adapter and gasket (1) 4 TOOLS NEEDED FOR INSTALLATION (NOT SUPPLIED WITH THE APPLIANCE) IMPORTANT! ● ● THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a qualified installer, service agent, or the gas supplier.
5 MODEL IDENTIFICATION Model features may vary OR90 MODELS OR90SCG1 OR90SCG2 OR90SCG4 OR90SCG6 OR90SDG6 6 PRIOR TO INSTALLATION Unpacking and handling ● ● ● 6 Inspect the range to verify that there is no shipping damage. If any damage is detected, call the shipper and initiate a damage claim. Fisher & Paykel is not responsible for shipping damage. DO NOT discard any packing material until the range has been inspected. Remove the outer carton and any packing material from range.
PRODUCT DIMENSIONS NOTE: Model features may vary Optional kickstrip is available (purchased separately) C D E A F G FRONT B SIDE OR90 DUAL FUEL PRODUCT DIMENSIONS A Overall height of range (from floor to top of cooktop, excluding grates and optional backguard) C mm min.
CLEARANCE DIMENSIONS ● B C A B COOKING SURFACE F ● E Electrical & Gas (see diagrams following) D ISO ● FRONT OR90 DUAL FUEL CLEARANCE DIMENSIONS mm ● A Minimum vertical distance between benchtop and cabinet extending above counter 450 B Minimum clearance from left and right edge of cooker to nearest vertical combustible surface* 200 C Minimum clearance from cooking surface to: – Overhead cabinet centered above the cooktop (combustible/unprotected)* – Overhead cabinet centered above the
FITTING THE OPTIONAL BACKGUARD !0 LOCATION OF ELECTRICAL SUPPLY Backguard (supplied with some models only) ● ● ● Remove the screws and spacers on the rear of the cooktop. Assemble the backguard as shown and fix onto the back of the range using the same screws and spacers. Fix the backguard onto the range using the screws provided.
!1 VENTILATION REQUIREMENTS A suitable ventilation hood may be installed above the range. Fisher & Paykel has a choice of ventilation hoods designed to match the rest of our kitchen appliance family. See fisherpaykel.com or your local dealer for more details. Hood (inc. combustible) 750mm Wall Installation Hood (inc.
!2 FITTING THE ADJUSTABLE FEET Fitting the adjustable feet Fitting the adjustable feet covers (optional) The adjustable feet must be fitted to the base of the range before use. Rest the rear of the range on a piece of the polystyrene packaging exposing the base for the fitting of the feet. If using the adjustable feet covers fit these while the range is tipped over. IMPORTANT Take care not to damage the range during this operation.
!3 MOVING THE RANGE IMPORTANT! ● ● ● 12 When raising range to upright position always ensure two people carry out this manoeuvre to prevent damage to the adjustable feet. Be careful: do not lift the range by the oven door handle, the hob rail or by lifting the cooktop trim as this may damage the appliance. When moving range to its final position DO NOT DRAG. Lift feet clear of floor.
!4 INSTALLING THE ANTI-TIP BRACKET IMPORTANT! ● ● ● To restrain the range and prevent it tipping accidentally secure the range to the wall using the supplied anti-tip bracket. Make sure you also fit the supplied lock pin to the anti-tip bracket. If installing the range above a plinth (without fitting the adjustable feet) revise the installation dimensions for the anti-tip bracket accordingly, considering that the feet have the following measurements: min 85mm - max 133mm.
!4 INSTALLING THE ANTI-TIP BRACKET Fitting the lock pin (models with a storage/warming drawer) Fitting the lock pin (models with a storage compartment) The anti-tip bracket is accessible by removing the storage/warmer drawer, and is positioned on the rear right side of the range. The anti-tip bracket is accessible by opening the storage compartment door., and is positioned on the rear right side of the range. B A 1 Open the storage compartment door.
!5 ELECTRICAL CONNECTION IMPORTANT! ● ● ● ● ● ● ● ● ● ● ● ● This range must be connected to the mains power supply only by a suitably qualified person. This range must be earthed. If the installation requires alterations to the domestic electrical system, call a qualified electrician. The electrician should also check that the electrical system is suitable for the electricity drawn by the cooker.
!6 CONNECTION OF THE POWER SUPPLY CABLE IMPORTANT! ● ● The power supply cable must be connected by an authorised service person DO NOT unscrew the screws fixing the cover plate behind the terminal block OR90SG6 MODELS ONLY 220-240V AC 1 L 2 3 4 N 5 PE cable clamp 1 Unhook the terminal board cover by inserting a screwdriver into the two hooks at the base of the block. 2 Unscrew the screw to open the cable clamp. For OR90SCG6 and OR90SDG6 models, connect the U bolts onto the terminal.
!7 GAS CONNECTION Gas connection specification Gas supply ● ● ● ● ● The connection must be performed by an authorised person according to the relevant standards. This appliance is suitable for use with Natural Gas or ULPG. The gas range is shipped from the factory set and adjusted for Natural Gas. It can be converted for use with ULPG following the instructions in this manual. The connection must be made at the rear of appliance. Ensure the pipe does not cross the cooker.
!7 GAS CONNECTION IMPORTANT! The connection must be performed by an authorised person according to the relevant standards. Natural Gas ULPG 1 Before connecting the appliance to the gas main, mount the brass conical adaptor onto the gas inlet pipe, ensuring the supplied gasket is positioned between. Natural Gas Connect gas supply to the pressure regulator and adjust the regulator to obtain a test point pressure of 1 kPa with the two semi-rapid (SR) burners operating at maximum.
!8 FLAME TESTING ● ● ● The operation of the appliance must be tested when installation is completed. Turn on the appliance gas controls and light each burner individually and in combination. Check for a well defined blue flame without any yellow tipping. If any abnormality is evident then check that the burner cap is located properly and the injector nipple is aligned correctly. Check the minimum burner setting by quickly rotating the gas control knob from the maximum to the minimum position.
@0 GAS CONVERSION Replacing the cooktop burner injectors Conversion to ULPG ● ● ● ● 1 Remove the pan supports, the burner caps and the flame spreaders. 2 Using a wrench substitute the nozzle injectors with those most suitable for the kind of gas for which it is to be used. 3 Adjust the minimum burner setting (see “Adjusting the minimum burner setting”) 4 Refit the flame spreaders, the burner caps and the pan supports.
@1 ADJUSTING THE MINIMUM BURNER SETTINGS Adjusting the cooktop burner minimums ● ● ● Check whether the flame spreads to all burner ports when the burner is lit with the gas tap set to the minimum position. If some ports do not light, increase the minimum gas rate setting. Check whether the burner remains lit even when the gas tap is turned quickly from the maximum to the minimum position. If the burner does not remain lit, increase the minimum gas rate setting.
@2 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER F GENERAL Placement of unit. F Specified clearance maintained to cabinet surfaces. F Unit Level – front to back, side to side. F OPERATION All internal packing materials removed. Check below the cooktop grates and inside the oven. F If converted for use with ULPG, confirm that the test point adapter and cooktop burner injectors have been correctly set for use with ULPG. All packaging material and tie straps removed.
FISHERPAYKEL.COM © Fisher & Paykel Appliances 2017. All rights reserved. The product specifications in this booklet apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time. You should therefore check with your Dealer to ensure this booklet correctly describes the product currently available. NZ AU 591516A / 1105505-ß0 12.