Installation Guide

16
!6CONNECTION OF THE POWER SUPPLY CABLE
IMPORTANT!
The power supply cable must be connected by an authorised service person
DO NOT unscrew the screws fixing the cover plate behind the terminal block
Feeder cable section
Use a type of cable according to the applicable local regulations.
OR90SG6 MODELS ONLY
cable clamp
MODEL CODE CABLE SPECIFICATIONS
OR90SCG1 220-240 V 50Hz 3210 W (13.95 A) 3 x 1,5 mm **
OR90SCG2 220-240 V 50Hz 4950 W (21.54 A) 3 x 2,5 mm *
OR90SCG4 220-240 V 50Hz 4950 W (21.54 A) 3 x 2,5 mm *
OR90SCG6 220-240 V 50Hz 5200 W (22.60 A) 3 x 2,5 mm *
OR90SDG6 220-240 V 50Hz 5200 W (22.60 A) 3 x 2,5 mm *
* Connection with wall box connection.
** Connection possible with plug and outlet or with wall box connection.
PE
L
N
1
2
3
4
5
220-240V AC
1 Unhook the terminal board cover by inserting a
screwdriver into the two hooks at the base of the
block.
2 Unscrew the screw to open the cable clamp.
For OR90SCG6 and OR90SDG6 models, connect the
U bolts onto the terminal.
3 Connect the phase, neutral and earth wires to the
terminal board as shown. Strain the feeder cable and
block it with cable clamp. Screw clamp shut before
closing the main cover.
cable clamp
PE
L
N
220-240V AC