Installation Guide

18
!7GAS CONNECTION
Natural Gas
ULPG
2 Tighten connection 3 The connection must be made at the rear of
appliance as shown above.
The pipe should not cross the back of the
range
IMPORTANT!
Use two wrenches to tighten the connection.
Do not over tighten the connector.
Over tightening may crack regulator.
IMPORTANT!
The inlet not used must be closed off with
the cap and sealing gasket supplied.
IMPORTANT!
The connection must be performed by an authorised person
according to the relevant standards.
1 Before connecting the appliance to the gas main,
mount the brass conical adaptor onto the gas inlet
pipe, ensuring the supplied gasket is positioned
between.
Natural Gas
Connect gas supply to the pressure regulator and
adjust the regulator to obtain a test point pressure of
1 kPa with the two semi-rapid (SR) burners operating
at maximum.
LP/Propane
Connect gas supply to the test point adaptor and
ensure that the supply pressure is regulated to
2.75 kPa