Installation Guide
Table Of Contents
- Safety and warnings
- General installation information
- Parts supplied for installation
- Tools needed for installation (not supplied with the appliance)
- Model identification
- Prior to installation
- Product dimensions
- Clearance dimensions
- Fitting the optional backguard
- Location of electrical supply
- Ventilation requirements
- Fitting the adjustable feet
- Moving the range
- Installing the anti-tip bracket
- Electrical connection
- Connection of the power supply cable
- Gas connection
- Flame testing
- Leak testing
- Gas conversion
- Adjusting the minimum burner settings
- Final checklist
17
2 Tighten connection
IMPORTANT!
Use two wrenches to tighten the connection.
Do not over tighten the connector.
Over tightening may crack regulator.
3 The connection must be made at the rear of
appliance as shown above.
z
The pipe should not cross the back of the range
IMPORTANT!
The inlet not used must be closed off with the
cap and sealing gasket supplied.
IMPORTANT!
The connection must be performed by an authorised person
according to the relevant standards.
1 Before connecting the appliance to the gas main, mount the brass
conical adaptor onto the gas inlet pipe, ensuring the supplied
gasket is positioned between.
Natural Gas
z
Connect gas supply to the pressure regulator and adjust the
regulator to obtain a test point pressure of
z
1 kPa with the two semi-rapid (SR) burners operating at maximum.
LP/Propane
z
Connect gas supply to the test point adaptor and ensure that the
supply pressure is regulated to 2.75 kPa
GAS CONNECTION
Natural Gas
ULPG