Installation Guide

18
z
The operation of the appliance must be tested when installation is completed.
z
Turn on the appliance gas controls and light each burner individually and in combination. Check for a well defined blue flame without any yellow tipping.
If any abnormality is evident then check that the burner cap is located properly and the injector nipple is aligned correctly.
z
Check the minimum burner setting by quickly rotating the gas control knob from the maximum to the minimum position. The flame must not go out.
If adjustment is required see section “Adjusting the minimum burner setting”
If correct burner operation cannot be achieved, the installer shall check the installation and contact the local gas supply authority to ensure there are no gas
supply problems. If correct operation still cannot be achieved contact Customer Service.
FLAME TESTING
z
Ensure all oven and burner knobs are set to OFF before
connecting range to gas supply.
z
After final gas connection is made, turn gas supply on and test
all connections in gas supply piping for gas leaks with a soapy
water solution.
z
In order to avoid property damage or serious personal injury,
never use a Iighted match or open flame.
If a leak is present, tighten joint or unscrew, apply more joint
compound, tighten again and retest connection for leak.
LEAK TESTING
ON
GAS
lifting off Good flameyellow tip