Installation Guide
Table Of Contents
- Safety and warnings
- General installation information
- Parts supplied for installation
- Tools needed for installation (not supplied with the appliance)
- Model identification
- Prior to installation
- Product dimensions
- Clearance dimensions
- Fitting the optional backguard
- Location of electrical supply
- Ventilation requirements
- Fitting the adjustable feet
- Moving the range
- Installing the anti-tip bracket
- Electrical connection
- Connection of the power supply cable
- Gas connection
- Flame testing
- Leak testing
- Gas conversion
- Adjusting the minimum burner settings
- Final checklist
19
Conversion to ULPG
z
This range can be used with Natural Gas or ULPG. It is shipped from the factory adjusted
for use with Natural gas.
z
Any conversion required must be performed by an authorised person or service agent.
z
The range is supplied with a set of injectors required for converting the range burners.
z
Refer to the following table to select the appropriate size injector. The nozzle diameters
(hundredths of a millimetre) are marked on the body of each injector.
IMPORTANT!
z
After converting the range repeat flame testing.
z
If the range has been disconnected and re-connected to the gas supply line
repeat leak testing.
z
After conversion to ULPG gas affix the supplied conversion label near the data plate
on the product, as well as at the beginning of this manual.
z
If the range is being converted for use ULPG, before connecting to the gas mains
remove the appliance gas regulator and replace with test point adaptor.
Injectors table
BURNERS
NATURAL GAS
1 KPA
GAS
CONSUMPTION
ULPG
2.75 KPA
GAS
CONSUMPTION
Ø INJECTOR
MM
MJ/HR
Ø INJECTOR
MM
MJ/HR
Auxiliary (A) 0.92 3.90 0.56 3.90
Semirapid (SR) 1.17 6.5 0.70 5.8
Rapid (R) 1.54 11.50 0.98 11.50
Triple Ring (TR) 1.75 14.40 1.07 14.40
Dual (D)
Inner crown
injector
Outer crown
injector (x2)
0.76 16.20
1
0.48 14.9
1
1.23 16.20
1
0.71 14.9
1
1
Power calculated with inner and outer crown operating
Replacing the cooktop burner injectors
1 Remove the pan supports, the burner caps and the flame spreaders.
2 Using a wrench substitute the nozzle injectors with those most suitable for the kind of
gas for which it is to be used.
3 Adjust the minimum burner setting (see “Adjusting the minimum burner setting”)
4 Refit the flame spreaders, the burner caps and the pan supports.
5 Fix the warning label (supplied with the conversion kit) stating that the cooker has been
converted for use with ULPG to the rear of the range. Ensure it is in close proximity to
to the gas inlet connection.
The burners are designed so that no regulation of the primary air is required.
GAS CONVERSION
Auxiliary, Semi-rapid and
Rapid burners
Triple ring burners
Dual burner
injector injector
inner
crown
Injector
outer crown
Injectors