Adjusting the cooktop burner minimums
Check whether the flame spreads to all burner ports when the burner is lit with the gas tap
set to the minimum position.
z
If some ports do not light, increase the minimum gas rate setting.
z
Check whether the burner remains lit even when the gas tap is turned quickly from the
maximum to the minimum position.
z
If the burner does not remain lit, increase the minimum gas rate setting.
To regulate the flame follow these instructions:
Auxilliary, Rapid, Semi-rapid, Triple-ring and Single Wok burners (A)
z
Light the burner.
z
Set the gas valve to position (minimum rate).
z
Remove the knob.
z
With a thin screwdriver, turn the regulation screw inside the tap rod
until adjustment is correct.
Inner crown Dual Wok burner (B)
(OR90SG2, OR90SG4, OR90SDG6 and OR90SG6 models only)
z
Light the dual wok burner.
z
Set the gas valve to position (minimum rate of inner crown).
z
Remove the knob.
z
With a thin screwdriver, turn the regulation screw until adjustment is correct.
z
The screw is accessible via a hole in the microswitch.
Outer crown Dual Wok burner (C)
(OR90SG2, OR90SG4, OR90SDG6 and OR90SG6 models only)
z
Light the dual wok burner.
z
Set the gas valve to position.
(minimum rate of outer crown and maximum rate of inner crown).
z
Remove the knob.
z
With a thin screwdriver, turn the regulation screw inside the tap rod
until adjustment is correct.
z
For ULPG, tighten the adjustment screws completely.
Lubrication of the gas valves
z
If a gas valve becomes stiff, it is necessary to dismantle it carefully and clean it with
petroleum spirit.
z
Specialist high temperature resistant grease should be used to lubricate the valve
before replacing.
z
This must be carried out by an authorised person or service agent.