Installation Guide
Table Of Contents
- Safety and warnings
- General installation information
- Parts supplied for installation
- Tools needed for installation (not supplied with the appliance)
- Model identification
- Prior to installation
- Product dimensions
- Clearance dimensions
- Fitting the optional backguard
- Location of electrical supply
- Ventilation requirements
- Fitting the adjustable feet
- Moving the range
- Installing the anti-tip bracket
- Electrical connection
- Connection of the power supply cable
- Gas connection
- Flame testing
- Leak testing
- Gas conversion
- Adjusting the minimum burner settings
- Final checklist
6
PRODUCT DIMENSIONS
PLAN
B
C
FRONT
EA
F
PROFILE
C
D
G
Note: Model features may vary
Optional kickstrip is available (purchased separately)
PRODUCT DIMENSIONS
OR90 DUAL FUEL
MM
A Overall height of range
(from floor to top of cooktop, excl. grates and optional backguard)
min 898
max 946
B Overall width of range
897
C Overall depth of range
(from front of range to rear of backguard, excl. handles and dials)
600
D Height of optional backguard from top of cooktop
(supplied with some models only)
60
E Height of chassis (excl. adjustable feet) 813
F Adjustable feet height min 85
max 133
G Depth of open door to front of range 451