Installation Guide

7
f
B
D
C
A
E
B
Cooking surface
Electrical & Gas
(see diagrams following)
CLEARANCE DIMENSIONS
Note
Overhead Clearances
z
In no case shall the clearances between
the highest part of the cooker be
less than 650mm for a combustible /
unprotected cabinet or for an overhead
ventilation hood. All other downward
facing combustible surfaces less than
650 mm above the cooker surface shall
be protected for the full width of the
cooking surface in accordance with the
standards noted above. In no case shall
the clearance be less than 450 mm.
z
Where the dimensions from the periphery
of the nearest burner to any vertical
combustible surface is less than 200
mm the surface shall be protected in
accordance with the standards to a
height of not less than 150 mm above
the cooking surface for the full width or
depth of the cooking surface.
z
Where the dimensions from the periphery
of the nearest burner to any horizontal
combustible surface is less than 200
mm, the horizontal surface shall be
greater than 10 mm below the surface
of the hob, or the horizontal surface
requirement above.
z
Do not install the range near flammable
materials such as curtains.
z
Installing the range on a plinth
z
The range can be installed on a plinth
without the adjustable feet fitted.
z
Ensure the range is secure and provide
safety measures to keep it in place.
z
Cabinetry dimensions can be adjusted
to suit the plinth height, see product
dimensions for chassis height.
CLEARANCE DIMENSIONS
OR90 DUAL FUEL
MM
A Minimum vertical distance between benchtop and cabinet extending above counter 450
B Minimum clearance from left and right edge of cooker to nearest vertical combustible surface*
200
C Minimum clearance from cooking surface to:
Overhead cabinet centered above the cooktop (combustible/unprotected)*
Overhead cabinet centered above the cooktop (non-combustible/protected)*
Ventilation hood centered above the cooking surface
650
450
650
D Width of cabinetry opening 900
E Maximum height of cabinetry immediately adjacent to the range (from floor to countertop)** 946
F Maximum depth from wall to cabinetry face 600
*Installation clearances and protection of combustible surfaces shall comply with the current local regulations eg. AS/NZS5601.1 (latest edition) Gas
Installations code. The standards above specify that where required protection shall ensure that the surface temperature of the combustible surface
does not exceed 65°C above room temperature.
**Depending on the height of the feet adjustment. The cooking surface must sit flush or above countertop level.
ISO FRONT