ELECTRICAL CONNECTION
IMPORTANT!
z
This cooker must be connected to the mains power supply only
by a suitably qualified person. This cooker must be earthed.
z
If the installation requires alterations to the domestic electrical system, call a qualified electrician. The electrician should also
check that theelectrical system is suitable for the electricity drawn by the cooker.
z
The appliance must be connected to the mains electricity supply, checking that the voltage corresponds to the value given in
the rating plate and that the electrical cable sections can withstand the load specified on the plate.
z
A suitable disconnection switch must be incorporated in the permanent wiring, mounted and positioned to comply with the
local wiring rules and regulations. Theswitch must be of an approved type installed in the fixed wiring and provide a 3mm air
gap contact separation inall poles in accordance with the local wiringrules.
z
A switch of the approved type with a 3mm air gap must be installed in the active (phase) conductor of the fixed wiring.
z
The switch must always be accessible.
z
The power supply cable must not touch any hot parts and must be positioned so that it does not exceed 75°C at any point.
z
This cooker must be connected to a suitable double pole control unit adjacent to the cooker. No diversity can be applied to
this control unit.
z
This appliance must be connected to the electrical supply using a cable fitted with an appropriately rated plug. The plug must
be compatible with the socket-outlet fitted to the final subcircuit in the fixed wiring that is intended to supply the appliance.
Replacing the power cord
z
Replacements should only be made by a qualified electrician.
z
Use a cable according to the applicable local regulations.
MODEL CODE MAX POWER (W) HZ VOLTAGE (V)
MAX CURRENT PER PHASE (A)
1 PH 2 PH 3 PH
OR90S*1 10610 50 Hz 220 – 240 V~ 46 32 16
OR90S*4 15300 50 Hz 220 – 240 V~ 67 45 32
OR90S*6 15550 50 Hz 220 – 240 V~ 68 45 32