COMPANION PRODUCTS Coffee Maker EB24 Steam Oven OS24N Speed Oven OM24N models INSTALLATION GUIDE US CA 591496G 01.
CONTENTS Coffee maker 3 Steam oven 11 Speed oven 19 1 Safety and warnings 4 1 Safety and warnings 12 1 Safety and warnings 20 2 Parts supplied 5 2 Prior to installation 13 2 Prior to installation 21 3 Prior to installation 5 3 After installation 13 3 After installation 21 4 After installation 5 4 Product dimensions 14 4 Product dimensions 22 5 Product dimensions 6 5A Cabinetry dimensions (18 1/8" (460mm) high cavity) 15 5A Cabinetry dimensions (18 1/8" (460mm)
COFFEE MAKER EB24 models 560.00 12.95 00.00 20.
1 SAFETY AND WARNINGS IMPORTANT SAFETY INSTRUCTIONS! ● Installation ● WARNING! ● ● Cut Hazard Take care – some edges are sharp. Failure to use caution could result in injury or cuts. ● ● ● Checking for transport damage After removing the packaging, make sure the product is complete and undamaged and that all accessories are present. Do not use the appliance if it is visibly damaged. Contact Customer Care.
2 Screws (28) PARTS SUPPLIED Clip (1) Rails (2) Spacers (4) for side (4) for bottom 3 ● ● ● ● ● ● ● ● ● PRIOR TO INSTALLATION The countertop and coffee maker cavity are square and level, and are the required dimensions. 560.00 The installation will comply with all clearance requirements and applicable standards and regulations. The isolating switch will be easily accessible to the customer with the coffee maker installed. 352.
5 PRODUCT DIMENSIONS E H C F D SIDE TOP B I PRODUCT DIMENSIONS A Overall height of product A B Overall width of product C FRONT Overall depth of product (excluding dials) COFFEE MAKER INSTALLATION GUIDE 18" (458) 23 1/2" (596) 18 7/8" (480) 17 1/2" (445) E Width of chassis 22 1/16" (560) F Depth of chassis 18 1/8" (460) G Depth of coffee maker frame and control panel Stepdown control panel to chassis I Height of control panel | inches (mm) D Height of chassis H 6 EB24 MODELS 13/1
6A CABINETRY DIMENSIONS (18 1/8" (460mm) HIGH CAVITY) Verify the minimum measurements required for correct installation of the appliance. The coffee maker must be installed in a column and the column must be firmly fixed to the wall with commercially available brackets. IMPORTANT! PROUD INSTALL All installation or maintenance operations must be performed with the appliance disconnected from the mains electricity supply.
6B CABINETRY DIMENSIONS (18 7/8" (480mm) CAVITY TRIM KIT) Verify the minimum measurements required for correct installation of the appliance. The coffee maker must be installed in a column and the column must be firmly fixed to the wall with commercially available brackets. Lower Trim Kit The Lower Trim kit shown is available to order separately from fisherpaykel.com. To install the trim kit, refer to the instructions which accompany it.
7 INSTALLATION INSTRUCTIONS " 0.07 ) m (1.8m approx. 13 3/4" (350mm) 1 Position the rails on the sides of the cabinet. Fix with the screws provided, then extract them completely. ● If the coffee maker is installed over a warmer drawer, use the top surface of this as a reference to position the rails. ● In this case, there will be no surface to rest the rails on. 2 Fix the power cable with the clip.
8 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER F Make sure the coffee maker is level and securely fitted to the cabinetry. F Check the lower trim is undamaged. F Check there is adequate clearance. This is to ensure correct air circulation. F Make sure any cable ties and internal packaging has been removed from the coffee maker cavity. F Make sure all coffee maker vents and openings are clear and free of any obstruction or damage.
STEAM OVEN OS24N models 42.00 556.00 565.30 5 22.
1 SAFETY AND WARNINGS Installation ● WARNING! Electrical Shock Hazard Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains electricity supply. Connection to a good ground wiring system is absolutely essential and mandatory. Alterations to the domestic wiring system must only be made by a qualified electrician Failure to follow this advice may result in electrical shock or death.
2 ● ● ● ● ● ● ● ● ● PRIOR TO INSTALLATION The countertop and oven cavity are square and level, and are the required dimensions. 560.00 The installation will comply with all clearance requirements and applicable standards and regulations. The isolating switch will be easily accessible to the customer with the oven installed. 352.00 The electrician provides sufficient free length of power supply cable to reach from the bottom rear of the cavity to at least 59 1/16" (1.
4 PRODUCT DIMENSIONS E C F D G TOP SIDE H B PRODUCT DIMENSIONS A Overall height of product A B Overall width of product C FRONT Overall depth of product (excluding handle and dials) STEAM OVEN INSTALLATION GUIDE 18" (458) 23 7/16" (596) 22 1/8" (562) 17 1/2" (445) E Width of chassis 21 7/8" (556) F Depth of chassis 21 1/4" (540) G Depth of oven frame and control panel 7/8" (22) (=distance between front of chassis and front of oven door, excl.
5A CABINETRY DIMENSIONS (18 1/8" (460mm) HIGH CAVITY) The oven can be installed under a cooktop, in a column, or combined with the companion warmer drawer. The cabinet material must be able to withstand heat. The oven must be centered within the walls of the cabinet and fixed with the screws and bushings that are provided.
5B ● ● ● CABINETRY DIMENSIONS (18 7/8" (480mm) CAVITY TRIM KIT) The oven must be installed under a cook top, in a column, or combined with the companion warmer drawer. The cabinet material must be able to withstand heat. The oven must be centred within the walls of the cabinet and fixed with the screws and bushings that are provided. Lower Trim Kit The Lower Trim kit shown is available to order separately from fisherpaykel.com. To install the trim kit, refer to the instructions which accompany it.
6 ● ● ELECTRICAL HOOK-UP Before connecting to the electricity, make sure that the: specifications of the electrical system match with what is detailed on this section. (Fig. 1) system has an effective ground connection compliant with current standards and laws. The ground connection is required by law. The cable must not, at any point, reach a temperature greater than 122°F (50°C) above room temperature.
8 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER F Make sure the oven is level and securely fitted to the cabinetry. F Check the lower trim is undamaged. F Open the oven door slowly until it is fully open and check there is adequate clearance between the bottom of the door and the lower trim. This is to ensure correct air circulation. Should the lower trim become damaged, straighten the trim and ensure the oven door opens fully without obstruction.
SPEED OVEN OM24N models 42.00 556.00 565.30 35 22.
1 SAFETY AND WARNINGS Installation ● WARNING! Electrical Shock Hazard Before carrying out any work on the electrical section of the appliance, it must be disconnected from the mains electricity supply. Connection to a good ground wiring system is absolutely essential and mandatory. Alterations to the domestic wiring system must only be made by a qualified electrician Failure to follow this advice may result in electrical shock or death.
2 ● ● ● ● ● ● ● ● ● PRIOR TO INSTALLATION The countertop and oven cavity are square and level, and are the required dimensions. 560.00 The installation will comply with all clearance requirements and applicable standards and regulations. The isolating switch will be easily accessible to the customer with the oven installed. 352.00 The electrician provides sufficient free length of power supply cable to reach from the bottom rear of the cavity to at least 59 1/16" (1.
4 PRODUCT DIMENSIONS E C F D G TOP SIDE H B PRODUCT DIMENSIONS A Overall height of product A B Overall width of product C FRONT Overall depth of product (excluding handle and dials) SPEED OVEN INSTALLATION GUIDE 18" (458) 23 7/16" (596) 22 1/8" (562) 17 1/2" (445) E Width of chassis 21 7/8" (556) F Depth of chassis 21 1/4" (540) G Depth of oven frame and control panel 7/8" (22) (=distance between front of chassis and front of oven door, excl.
5A CABINETRY DIMENSIONS (18 1/8" (460mm) HIGH CAVITY) The oven can be installed under a cooktop, in a column, or combined with the companion warmer drawer. The cabinet material must be able to withstand heat. The oven must be centered within the walls of the cabinet and fixed with the screws and bushings that are provided.
5B ● ● ● CABINETRY DIMENSIONS (18 7/8" (480mm) CAVITY TRIM KIT) The oven must be installed under a cook top, in a column, or combined with the companion warmer drawer. The cabinet material must be able to withstand heat. The oven must be centred within the walls of the cabinet and fixed with the screws and bushings that are provided. Lower Trim Kit The Lower Trim kit shown is available to order separately from fisherpaykel.com. To install the trim kit, refer to the instructions which accompany it.
6 ● ● ELECTRICAL HOOK-UP Before connecting to the electricity, make sure that the: specifications of the electrical system match with what is detailed on this section. (Fig. 1) system has an effective ground connection compliant with current standards and laws. The ground connection is required by law. The cable must not, at any point, reach a temperature greater than 122°F (50°C) above room temperature.
8 FINAL CHECKLIST TO BE COMPLETED BY THE INSTALLER F Make sure the oven is level and securely fitted to the cabinetry. F Check the lower trim is undamaged. F Open the oven door slowly until it is fully open and check there is adequate clearance between the bottom of the door and the lower trim. This is to ensure correct air circulation. Should the lower trim become damaged, straighten the trim and ensure the oven door opens fully without obstruction.