3 0 " P R O F E SSI O NAL R A N GE S & B AC KG UARDS — RGV2-304, RDV2-304, RGV2-305, RDV2-305, BGRV2-1230, BGRV2-3030, BGRV2-3030H models PLANNING GUIDE
CONTENTS PAGE 30" Professional Range RGV2-304 & RDV2-304, RGV2-305, RDV2-305 in mm Key Design Decisions 5 17 Ventilation Requirements 6 18 Product & Cavity Dimensions 7 19 Clearance Dimensions 8 20 Cavity Preparation 9 21 Product & Cavity Dimensions 10 22 Clearance Dimensions 11 23 Cavity Preparation 12 24 30" Professional Range RGV2-304 & RDV2-304 30" Professional Range RGV2-305, RDV2-305
CONTENTS (continued) 30" Professional Range Backguard BGRV2-1230 PAGE in mm Product Dimensions 13 25 Product Dimensions 14 26 30" Professional Range Backguard BGRV2-3030H in mm Product Dimensions 15 27 30" Professional Range Backguard BGRV2-3030
IMPERIAL
1 2 3 INSTALL TYPE REAR SURFACE BACKGUARD OPTIONS KEY DESIGN DECISIONS 30" Professional Range Model no: RGV2-304, RDV2-304 RGV2-305, RDV2-305 BGRV2-3030H ANGLED TRIM (Supplied with backguard) BGRV2-1230 MIN 6" CLEARANCE WALL COMBUSTIBLE NO BACKGUARD LOW THIN BACKGUARD HIGH THICK BACKGUARD WITH ANGLED TRIM BGRV2-3030 CUSTOM BACKGUARD* MIN 30" MAX 1/2" NON COMBUSTIBLE ISLAND CUSTOM FABRICATED* BACKGUARD HIGH THIN BACKGUARD *Fabricated from non combustible materials only. DATE: 24.04.
1 2 INSTALL TYPE HOOD SURROUND MATERIAL VENTILATION REQUIREMENTS 30" Professional Range Model no: RGV2-304, RDV2-304 RGV2-305, RDV2-305 (Note: RGV2-366 illustrated but all dimensions apply to the above models) Specifications 23" 23" Ventilation Unit Hood Blower Ventilation Unit MIN 30" MAX 36" MIN 36" Hood Blower Wall Installation 23'' Deep x Unit Width 600 CFM Island Installation 30'' Deep x Unit Width 600 CFM Note: A suitable hood must be installed above the range.
PRODUCT & CAVITY DIMENSIONS 30" Professional Range B 29 7/8'' Model no: RGV2-304-N, RGV2-304-L RDV2-304-N, RDV2-304-L Supplied with Integral Flat Vent Trim C Product Dimensions 29 1/8'' A Overall height of range (from floor to cooktop, excluding grates and vent trim) CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL B Overall width of range 29 7/8'' C Overall depth of range (excluding handle and dials) 29 1/8'' D Depth from rear of chassis to cabinetry face - projecting CABINET FACE F
CLEARANCE DIMENSIONS 30" Professional Range C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE E MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY RGV2-304-N, RGV2-304-L RDV2-304-N, RDV2-304-L Supplied with Integral Flat Vent Trim Clearance Dimensions CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL D MINIMUM CLEARANCE:
CAVITY PREPARATION 30" Professional Range RGV models Model no: RGV2-304-N, RGV2-304-L RDV2-304-N, RDV2-304-L FINAL POSITION OF RANGE AGAINST WALL ELECTRICAL in A Depth of supply area (ie maximum protrusion of gas connection from wall) 2'' B Distance from right hand edge of range to supply area GAS c Location of Electrical and Gas Supply d 1 1/2'' C (RGV) Height of electrical supply area (from floor) 19'' D (RGV) Height of gas supply area (from floor) 12'' E (RGV) Width of supply area 2''
PRODUCT & CAVITY DIMENSIONS 30" Professional Range B 29 7/8'' Model no: RGV2-305-N, RGV2-305-L RDV2-305-N, RDV2-305-L Supplied with Integral Flat Vent Trim C Product Dimensions 29 1/8'' A Overall height of range (from floor to cooktop, excluding grates and vent trim) CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL B Overall width of range 29 7/8'' C Overall depth of range (excluding handle and dials) 29 1/8'' D Depth from rear of chassis to cabinetry face - projecting CABINET FACE FO
CLEARANCE DIMENSIONS 30" Professional Range C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE RGV2-305-N, RGV2-305-L RDV2-305-N, RDV2-305-L Supplied with Integral Flat Vent Trim Clearance Dimensions E MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL D MINIMUM CLEARANCE:
CAVITY PREPARATION 30" Professional Range RGV models Model no: RGV2-305-N, RGV2-305-L RDV2-305-N, RDV2-305-L FINAL POSITION OF RANGE AGAINST WALL in A Depth of supply area (ie maximum protrusion of gas connection from wall) 2'' B Distance from right hand edge of range to supply area ELECTRICAL GAS c Location of Electrical and Gas Supply 1 1/2'' C (RGV) Height of electrical supply area (from floor) 19'' D (RGV) Height of gas supply area (from floor) 12'' E (RGV) Width of supply area d 2'' F
PRODUCT DIMENSIONS 30" Professional Range Backguard NOT TO SCALE BGRV2-1230 Model no: BGRV2-1230 Product Dimensions A Height of backguard above vent trim on range c 29 7/8'' B Overall height of backguard 15 15/16'' C Overall width of backguard 29 7/8'' D Overall depth of backguard DATUM : BACK OF PRODUCT in 10 3/8'' 1/2'' E Height of backguard below vent trim on range 5 9/16'' F Depth of backguard below vent trim on range 1/16'' PLAN VIEW RGV2-304/ RDV2-304 (illustrated) DATUM : BACK OF PRO
PRODUCT DIMENSIONS 30" Professional Range Backguard c 29 7/8" NOT TO SCALE BGRV2-3030 Model no: DATUM : BACK OF PRODUCT BGRV2-3030 Product Dimensions d f A Height of backguard above vent trim on range B Overall height of backguard 29 1/8" C Overall width of backguard 29 7/8" D Overall depth of backguard and racks 9 5/16" E Depth of backguard F Depth of racks G Width of racks H Distance from top of backguard to bottom of racks g RGV2-304/ RDV2-304 (illustrated) I Distance from bottom of backg
PRODUCT DIMENSIONS 30" Professional Range Backguard with Angled Vent Trim B 29 7/8'' NOT TO SCALE BGRV2-3030H Model no: DATUM : BACK OF BACKGUARD BGRV2-3030H f Product Dimensions A Overall height of backguard with angled vent trim c h RGV2-304/ RDV2-304 (illustrated) DATUM : BACK OF BACKGUARD in 30'' B Overall width of backguard 29 7/8'' C Overall depth of backguard and racks 10 3/8'' D Height of backguard 26 1/2'' E Height of angled vent trim 3 1/2'' F Depth of angled vent trim 2 7/8'' G
METRIC
1 2 3 INSTALL TYPE REAR SURFACE BACKGUARD OPTIONS KEY DESIGN DECISIONS 30" Professional Range Model no: RGV2-304, RDV2-304, RGV2-305, RDV2-305 BGRV2-3030H ANGLED TRIM (Supplied with backguard) BGRV2-1230 MIN 152mm CLEARANCE WALL COMBUSTIBLE NO BACKGUARD LOW THIN BACKGUARD CUSTOM BACKGUARD* HIGH THICK BACKGUARD WITH ANGLED TRIM BGRV2-3030 MIN 762mm MAX 24mm NON COMBUSTIBLE ISLAND CUSTOM FABRICATED* BACKGUARD HIGH THIN BACKGUARD *Fabricated from non combustible materials only. DATE: 24.
1 2 INSTALL TYPE HOOD SURROUND MATERIAL VENTILATION REQUIREMENTS 30" Professional Range Model no: RGV2-304, RDV2-304, RGV2-305, RDV2-305 (Note: RGV2-366 illustrated but all dimensions apply to the above models) 584mm 584mm Specifications Ventilation Unit Hood Blower MIN 762mm MAX 914mm Ventilation Unit 914mm Hood Blower Wall Installation 584mm Deep x Unit Width 600 CFM Island Installation 762mm Deep x Unit Width 600 CFM Note: A suitable hood must be installed above the range.
PRODUCT & CAVITY DIMENSIONS 30" Professional Range B 759 Model no: RGV2-304-N, RGV2-304-L RDV2-304-N, RDV2-304-L Supplied with Integral Flat Vent Trim C Product Dimensions 740 A Overall height of range (from floor to cooktop, excluding grates and vent trim) CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL B Overall width of range 759 C Overall depth of range (excluding handle and dials) 740 D Depth from rear of chassis to cabinet
CLEARANCE DIMENSIONS 30" Professional Range C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE RGV2-304-N, RGV2-304-L RDV2-304-N, RDV2-304-L Supplied with Integral Flat Vent Trim E MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL D MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFA
CAVITY PREPARATION 30" Professional Range RGV models Model no: RGV2-304-N, RGV2-304-L RDV2-304-N, RDV2-304-L FINAL POSITION OF RANGE AGAINST WALL Location of Electrical and Gas Supply mm A Depth of supply area (ie maximum protrusion of gas connection from wall) ELECTRICAL B Distance from right hand edge of range to supply area GAS c d b e 51 38 C (RGV) Height of electrical supply area (from floor) 483 D (RGV) Height of gas supply area (from floor) 305 E (RGV) Width of supply area 51 F (RD
PRODUCT & CAVITY DIMENSIONS 30" Professional Range B 759 Model no: RGV2-305-N, RGV2-305-L RDV2-305-N, RDV2-305-L Supplied with Integral Flat Vent Trim C Product Dimensions 740 A Overall height of range (from floor to cooktop, excluding grates and vent trim) CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL B Overall width of range 759 C Overall depth of range (excluding handle and dials) 740 D Depth from rear of chassis to cabinet
CLEARANCE DIMENSIONS 30" Professional Range C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE RGV2-305-N, RGV2-305-L RDV2-305-N, RDV2-305-L Supplied with Integral Flat Vent Trim E MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL D MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFA
CAVITY PREPARATION 30" Professional Range RGV models Model no: RGV2-305-N, RGV2-305-L RDV2-305-N, RDV2-305-L FINAL POSITION OF RANGE AGAINST WALL Location of Electrical and Gas Supply mm A Depth of supply area (ie maximum protrusion of gas connection from wall) B Distance from right hand edge of range to supply area ELECTRICAL GAS c d b e 51 38 C (RGV) Height of electrical supply area (from floor) 483 D (RGV) Height of gas supply area (from floor) 305 E (RGV) Width of supply area 51 F (RDV)
PRODUCT DIMENSIONS 30" Professional Range Backguard NOT TO SCALE BGRV2-1230 Model no: BGRV2-1230 Product Dimensions c 759 263 B Overall height of backguard 405 C Overall width of backguard 759 D Overall depth of backguard DATUM : BACK OF PRODUCT mm A Height of backguard above vent trim on range 13 E Height of backguard below vent trim on range 142 F Depth of backguard below vent trim on range 1 PLAN VIEW RGV2-304/ RDV2-304 (illustrated) DATUM : BACK OF PRODUCT d 13 c 759 A 263 b DATUM
PRODUCT DIMENSIONS 30" Professional Range Backguard c 759 NOT TO SCALE BGRV2-3030 Model no: DATUM : BACK OF PRODUCT BGRV2-3030 Product Dimensions d f 720 B Overall height of backguard 740 C Overall width of backguard 759 D Overall depth of backguard and racks 237 E Depth of backguard F Depth of racks G Width of racks g RGV2-304/ RDV2-304 (illustrated) PLAN VIEW DATUM : BACK OF PRODUCT c 759 e mm A Height of backguard above vent trim on range 13 224 711 H Distance from top of backguard
PRODUCT DIMENSIONS 30" Professional Range Backguard with Angled Vent Trim B 759 NOT TO SCALE BGRV2-3030H Model no: DATUM : BACK OF BACKGUARD BGRV2-3030H f Product Dimensions c 264 h 763 B Overall width of backguard 759 C Overall depth of backguard and racks 264 D Height of backguard 673 E Height of angled vent trim RGV2-304/ RDV2-304 (illustrated) DATUM : BACK OF BACKGUARD mm A Overall height of backguard with angled vent trim 90 F Depth of angled vent trim 72 G Depth of backguard 33
IMPORTANT: The product dimensions and specifications apply at the date of issue. Under our policy of continuous product improvement, these dimensions and specifications may change at any time. Dimensions may vary by ±2mm (1/16"). Please read the installation guide for detailed information on installing the product or visit fisherpaykel.com.