4 8" P R O F E SSI O NAL R A N GE S & B AC KG UARDS — RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488, RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488, RGV2-485GD-N, RGV2-486GD-N, RGV2-486GL-N, RGV2-488-N, RDV2-485GD-L, RDV2-486GD-L, RDV2-486GL-L, RDV2-488-L, BGRV2-1248, BGRV2-3048, BGRV2-3048H models PLANNING GUIDE
CONTENTS 48" Professional Range RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488 RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488 in mm Key Design Decisions 5 23 Ventilation Requirements 6 24 Product & Cavity Dimensions 7 25 Clearance Dimensions 8 26 Cavity Preparation 9 27 Product & Cavity Dimensions 10 28 Clearance Dimensions 11 29 Cavity Preparation 12 30 Product & Cavity Dimensions 13 31 Clearance Dimensions 14 32 Cavity Preparation 15 33 PAGE 48" Professional Range RGV2-48
CONTENTS (continued) 48" Professional Range RGV2-488-N, RDV2-488-L PAGE in mm Product & Cavity Dimensions 16 34 Clearance Dimensions 17 35 Cavity Preparation 18 36 19 37 20 38 21 39 48" Professional Range Backguard BGRV2-1248 Product Dimensions 48" Professional Range Backguard BGRV2-3048 Product Dimensions 48" Professional Range Backguard BGRV2-3048H Product Dimensions
IMPERIAL
KEY DESIGN DECISIONS 48" Professional Range 1 2 3 INSTALL TYPE REAR SURFACE BACKGUARD OPTIONS Model no: RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488 RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488 BGRV2-3048H ANGLED TRIM (Supplied with backguard) BGRV2-1248 MIN 6" CLEARANCE WALL COMBUSTIBLE HIGH THICK BACKGUARD WITH ANGLED TRIM NO BACKGUARD LOW THIN BACKGUARD BGRV2-3048 CUSTOM BACKGUARD* MIN 30" MAX 1/2" NON COMBUSTIBLE CUSTOM FABRICATED* BACKGUARD ISLAND HIGH THIN BACKGUARD *Fabricated from
VENTILATION REQUIREMENTS 48" Professional Range 1 2 INSTALL TYPE HOOD SURROUND MATERIAL Model no: RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488 RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488 Note: RGV2-366 illustrated but all dimensions apply to the above models Specifications 23" 23" Ventilation Unit Hood Blower Ventilation Unit MIN 30" MAX 36" MIN 36" Hood Blower Wall Installation 23'' Deep x Unit Width 1200 CFM Island Installation 30'' Deep x Unit Width 1200 CFM Note: A suitable hood must be i
PRODUCT & CAVITY DIMENSIONS 48" Professional Range B 47 7/8'' Model no: RGV2-485GD-N, RGV2GD-485-L RDV2-485GD-N, RDV2GD-485-L Product Dimensions C A Overall height of range (from floor to cooktop, excluding grates and vent trim) 29 1/8'' CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL B Overall width of range 47 7/8'' C Overall depth of range (excluding handle and dials) 29 1/8'' D Depth from rear of chassis to cabinetry face - projecting E Depth from rear of chassis to cabinetry face
CLEARANCE DIMENSIONS 48" Professional Range C C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D RGV2-485GD-N, RGV2-485GD-L MINIMUM CLEARANCE: COMBUSTIBLE SURFACE RDV2-485GD-N, RDV2-485GD-L Clearance Dimensions A Minimum width of ventilation hood installed above range - not shown* E CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL D MAXIMUM OVERALL DEPTH OF
CAVITY PREPARATION 48" Professional Range RGV models Model no: RGV2-485GD-N, RGV2-485GD-L RDV2-485GD-N, RDV2-485GD-L FINAL POSITION OF RANGE AGAINST WALL Location of Electrical and Gas Supply in A Depth of supply area (ie maximum protrusion of gas connection from wall) 2'' B Distance from right hand edge of range to supply area ELECTRICAL GAS C 1 1/2'' C (RGV) Height of electrical supply area (from floor) 19'' D (RGV) Height of gas supply area (from floor) 12'' E (RGV) Width of supply area D
PRODUCT & CAVITY DIMENSIONS 48" Professional Range B 47 7/8'' Model no: RGV2-486GD-N, RGV2-486GD-L RDV2-486GD-N, RDV2-486GD-L Product Dimensions C A Overall height of range (from floor to cooktop, excluding grates and vent trim) 29 1/8'' CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL B Overall width of range 47 7/8'' C Overall depth of range (excluding handle and dials) 29 1/8'' D Depth from rear of chassis to cabinetry face - projecting E Depth from rear of chassis to cabinetry face
CLEARANCE DIMENSIONS 48" Professional Range C C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D RGV2-486GD-N, RGV2-486GD-L MINIMUM CLEARANCE: COMBUSTIBLE SURFACE RDV2-486GD-N, RDV2-486GD-L Clearance Dimensions E CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL D MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFACE in A
CAVITY PREPARATION 48" Professional Range RGV models Model no: RGV2-486GD-N, RGV2-486GD-L RDV2-486GD-N, RDV2-486GD-L FINAL POSITION OF RANGE AGAINST WALL Location of Electrical and Gas Supply in A Depth of supply area (ie maximum protrusion of gas connection from wall) 2'' B Distance from right hand edge of range to supply area ELECTRICAL 19'' D (RGV) Height of gas supply area (from floor) 12'' E (RGV) Width of supply area GAS C 1 1/2'' C (RGV) Height of electrical supply area (from floor)
PRODUCT & CAVITY DIMENSIONS 48" Professional Range B 47 7/8'' Model no: RGV2-486GL-N, RGV2-486GL-L RDV2-486GL-N, RDV2-486GL-L Product Dimensions C A Overall height of range (from floor to cooktop, excluding grates and vent trim) 29 1/8'' CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL B Overall width of range 47 7/8'' C Overall depth of range (excluding handle and dials) 29 1/8'' D Depth from rear of chassis to cabinetry face - projecting E Depth from rear of chassis to cabinetry face
CLEARANCE DIMENSIONS 48" Professional Range C C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D RGV2-486GL-N, RGV2-486GL-L MINIMUM CLEARANCE: COMBUSTIBLE SURFACE RDV2-486GL-N, RDV2-486GL-L Clearance Dimensions A Minimum width of ventilation hood installed above range - not shown* E CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL D MAXIMUM OVERALL DEPTH OF
CAVITY PREPARATION 48" Professional Range RGV models Model no: RGV2-486GL-N, RGV2-486GL-L RDV2-486GL-N, RDV2-486GL-L FINAL POSITION OF RANGE AGAINST WALL Location of Electrical and Gas Supply in A Depth of supply area (ie maximum protrusion of gas connection from wall) 2'' B Distance from right hand edge of range to supply area ELECTRICAL GAS C 1 1/2'' C (RGV) Height of electrical supply area (from floor) 19'' D (RGV) Height of gas supply area (from floor) 12'' E (RGV) Width of supply area D
PRODUCT & CAVITY DIMENSIONS 48" Professional Range B 47 7/8'' Model no: RGV2-488-N, RGV2-488-L RDV2-488-N, RDV2-488-L Product Dimensions C A Overall height of range (from floor to cooktop, excluding grates and vent trim) 29 1/8'' CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL B Overall width of range 47 7/8'' C Overall depth of range (excluding handle and dials) 29 1/8'' D Depth from rear of chassis to cabinetry face - projecting E Depth from rear of chassis to cabinetry face - flush
CLEARANCE DIMENSIONS 48" Professional Range C C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D RGV2-488-N, RGV2-488-L MINIMUM CLEARANCE: COMBUSTIBLE SURFACE RDV2-488-N, RDV2-488-L Cabinetry Dimensions A Minimum width of ventilation hood installed above range - not shown* E CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL D MAXIMUM OVERALL DEPTH OF OVERHEA
CAVITY PREPARATION 48" Professional Range RGV models Model no: RGV2-488-N, RGV2-488-L RDV2-488-N, RDV2-488-L FINAL POSITION OF RANGE AGAINST WALL Location of Electrical and Gas Supply in A Depth of supply area (ie maximum protrusion of gas connection from wall) 2'' B Distance from right hand edge of range to supply area ELECTRICAL 19'' D (RGV) Height of gas supply area (from floor) 12'' E (RGV) Width of supply area GAS C 1 1/2'' C (RGV) Height of electrical supply area (from floor) D 3'' F
PRODUCT DIMENSIONS 48" Professional Range Backguard NOT TO SCALE BGRV2-1248 Model no: BGRV2-1248 Product Dimensions A Height of backguard above vent trim on range B Overall height of backguard c 47 7/8'' C Overall width of backguard D Overall depth of backguard DATUM : BACK OF PRODUCT RGV2-488/ RDV2-488 (illustrated) in 10 3/8'' 15 15/16'' 47 7/8'' 1/2'' E Height of backguard below vent trim on range 5 9/16'' F Depth of backguard below vent trim on range 1/16'' PLAN VIEW DATUM : BACK OF PRODUCT
PRODUCT DIMENSIONS 48" Professional Range Backguard NOT TO SCALE BGRV2-3048 C 47 7/8" Model no: BGRV2-3048 DATUM : BACK OF PRODUCT Product Dimensions A Height of backguard above vent trim on range D F B Overall height of backguard 29 1/8" C Overall width of backguard 47 7/8" D Overall depth of backguard and racks 9 5/16" E Depth of backguard F Depth of racks G Width of racks RGV2-488/ RDV2-488 (illustrated) H Distance from top of backguard to bottom of racks G I Distance from bottom of bac
PRODUCT DIMENSIONS 48" Professional Range Backguard with Angled Vent Trim NOT TO SCALE B 47 7/8" BGRV2-3048H Model no: BGRV2-3048H DATUM : BACK OF BACKGUARD Product Dimensions f A Overall height of backguard with angled vent trim c h B Overall width of backguard 47 7/8'' C Overall depth of backguard and racks 10 3/8'' D Height of backguard 26 1/2'' E Height of angled vent trim 3 1/2'' F Depth of angled vent trim 2 7/8'' G Depth of backguard RGV2-488/ RDV2-488 (illustrated) 1 5/16''' i H
METRIC
KEY DESIGN DECISIONS 48" Professional Range 1 2 3 INSTALL TYPE REAR SURFACE BACKGUARD OPTIONS Model no: RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488 RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488 BGRV2-3048H ANGLED TRIM (Supplied with backguard) BGRV2-1248 MIN 152mm CLEARANCE WALL COMBUSTIBLE HIGH THICK BACKGUARD WITH ANGLED TRIM NO BACKGUARD LOW THIN BACKGUARD BGRV2-3048 CUSTOM BACKGUARD* MIN 762mm MAX 12.
VENTILATION REQUIREMENTS 48" Professional Range 1 2 INSTALL TYPE HOOD SURROUND MATERIAL Model no: RGV2-485GD, RGV2-486GD, RGV2-486GL, RGV2-488 RDV2-485GD, RDV2-486GD, RDV2-486GL, RDV2-488 Note: RGV2-366 illustrated but all dimensions apply to the above models Specifications 584mm 584mm Ventilation Unit Hood Blower MIN 762mm MAX 914mm Ventilation Unit 914mm Hood Blower Wall Installation 584mm Deep x Unit Width 1200 CFM Island Installation 762mm Deep x Unit Width 1200 CFM Note: A suitable hood m
PRODUCT & CAVITY DIMENSIONS 48" Professional Range B 1216 Model no: RGV2-485GD-N, RGV2-485GD-L RDV2-485GD-N, RDV2-485GD-L Product Dimensions C A Overall height of range (from floor to cooktop, excluding grates and vent trim) 740 CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL B Overall width of range 1216 C Overall depth of range (excluding handle and dials) 740 D Depth from rear of chassis to cabinetry face - projecting 638 E D
CLEARANCE DIMENSIONS 48" Professional Range C C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D E CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D RGV2-485GD-N, RGV2-485GD-L MINIMUM CLEARANCE: COMBUSTIBLE SURFACE MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFACE RDV2-485GD-N, RDV2-485GD-L Clearance Dimensions mm A
CAVITY PREPARATION 48" Professional Range RGV models Model no: RGV2-485GD-N, RGV2-485GD-L RDV2-485GD-N, RDV2-485GD-L FINAL POSITION OF RANGE AGAINST WALL Location of Electrical and Gas Supply mm A Depth of supply area (ie maximum protrusion of gas connection from wall) 51 B Distance from right hand edge of range to supply area ELECTRICAL GAS C D B E 38 C (RGV) Height of electrical supply area (from floor) 483 D (RGV) Height of gas supply area (from floor) 305 E (RGV) Width of supply area 7
PRODUCT & CAVITY DIMENSIONS 48" Professional Range B 1216 Model no: RGV2-486GD-N, RGV2-486GD-L RDV2-486GD-N, RDV2-486GD-L Product Dimensions C A Overall height of range (from floor to cooktop, excluding grates and vent trim) 740 CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL B Overall width of range 1216 C Overall depth of range (excluding handle and dials) 740 D Depth from rear of chassis to cabinetry face - projecting 638 E D
CLEARANCE DIMENSIONS 48" Professional Range C C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D E CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D RGV2-486GD-N, RGV2-486GD-L MINIMUM CLEARANCE: COMBUSTIBLE SURFACE MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFACE RDV2-486GD-N, RDV2-486GD-L Clearance Dimensions mm A
CAVITY PREPARATION 48" Professional Range RGV models Model no: RGV2-486GD-N, RGV2-486GD-L RDV2-486GD-N, RDV2-486GD-L FINAL POSITION OF RANGE AGAINST WALL Location of Electrical and Gas Supply mm A Depth of supply area (ie maximum protrusion of gas connection from wall) 51 B Distance from right hand edge of range to supply area ELECTRICAL GAS C D B E 38 C (RGV) Height of electrical supply area (from floor) 483 D (RGV) Height of gas supply area (from floor) 305 E (RGV) Width of supply area 76
PRODUCT & CAVITY DIMENSIONS 48" Professional Range B 1216 Model no: RGV2-486GL-N, RGV2-486GL-L RDV2-486GL-N, RDV2-486GL-L Product Dimensions C A Overall height of range (from floor to cooktop, excluding grates and vent trim) 740 CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL B Overall width of range 1216 C Overall depth of range (excluding handle and dials) 740 D Depth from rear of chassis to cabinetry face - projecting 638 E D
CLEARANCE DIMENSIONS 48" Professional Range C C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D E CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D RGV2-486GL-N, RGV2-486GL-L MINIMUM CLEARANCE: COMBUSTIBLE SURFACE MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFACE RDV2-486GL-N, RDV2-486GL-L Clearance Dimensions mm A
CAVITY PREPARATION 48" Professional Range RGV models Model no: RGV2-486GL-N, RGV2-486GL-L RDV2-486GL-N, RDV2-486GL-L FINAL POSITION OF RANGE AGAINST WALL Location of Electrical and Gas Supply mm A Depth of supply area (ie maximum protrusion of gas connection from wall) B Distance from right hand edge of range to supply area ELECTRICAL GAS C D B E 51 38 C (RGV) Height of electrical supply area (from floor) 483 D (RGV) Height of gas supply area (from floor) 305 E (RGV) Width of supply area 76
PRODUCT & CAVITY DIMENSIONS 48" Professional Range B 1216 Model no: RGV2-488-N, RGV2-488-L RDV2-488-N, RDV2-488-L Product Dimensions C A Overall height of range (from floor to cooktop, excluding grates and vent trim) 740 CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL B Overall width of range 1216 C Overall depth of range (excluding handle and dials) 740 D Depth from rear of chassis to cabinetry face - projecting 638 E Depth fro
CLEARANCE DIMENSIONS 48" Professional Range C C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D E CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE D RGV2-488-N, RGV2-488-L MINIMUM CLEARANCE: COMBUSTIBLE SURFACE MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFACE RDV2-488-N, RDV2-488-L Clearance Dimensions mm A Minimum
CAVITY PREPARATION 48" Professional Range RGV models Model no: RGV2-488-N, RGV2-488-L RDV2-488-N, RDV2-488-L FINAL POSITION OF RANGE AGAINST WALL Location of Electrical and Gas Supply mm A Depth of supply area (ie maximum protrusion of gas connection from wall) B Distance from right hand edge of range to supply area ELECTRICAL GAS C D B E 51 38 C (RGV) Height of electrical supply area (from floor) 483 D (RGV) Height of gas supply area (from floor) 305 E (RGV) Width of supply area 76 F (RDV)
PRODUCT DIMENSIONS 48" Professional Range Backguard NOT TO SCALE BGRV2-1248 Model no: BGRV2-1248 Product Dimensions c 1210 263 B Overall height of backguard 405 C Overall width of backguard 1210 D Overall depth of backguard DATUM : BACK OF PRODUCT RGV2-488/ RDV2-488 (illustrated) mm A Height of backguard above vent trim on range 13 E Height of backguard below vent trim on range 142 F Depth of backguard below vent trim on range 1 PLAN VIEW DATUM : BACK OF PRODUCT c 1210 d 13 A 263 b
PRODUCT DIMENSIONS 48" Professional Range Backguard NOT TO SCALE BGRV2-3048 C 1216 Model no: BGRV2-3048 DATUM : BACK OF PRODUCT Product Dimensions D F 720 B Overall height of backguard 740 C Overall width of backguard 1216 D Overall depth of backguard and racks 237 E Depth of backguard RGV2-488/ RDV2-488 (illustrated) G PLAN VIEW DATUM : BACK OF PRODUCT mm A Height of backguard above vent trim on range 13 F Depth of racks 224 G Width of racks 1153 H Distance from top of backguard to
PRODUCT DIMENSIONS 48" Professional Range Backguard with Angled Vent Trim NOT TO SCALE B 1216 BGRV2-3048H Model no: BGRV2-3048H DATUM : BACK OF BACKGUARD Product Dimensions f c h 763 B Overall width of backguard 1216 C Overall depth of backguard and racks 264 D Height of backguard 673 E Height of angled vent trim RGV2-488/ RDV2-488 (illustrated) 90 F Depth of angled vent trim 72 G Depth of backguard 33 i H Depth of racks 230 PLAN VIEW I Width of racks 1152 J Distance from top of ba
IMPORTANT: The product dimensions and specifications apply at the date of issue. Under our policy of continuous product improvement, these dimensions and specifications may change at any time. Dimensions may vary by ±2mm (1/16"). Please read the installation guide for detailed information on installing the product or visit fisherpaykel.com.