3 0 " P R O F E SSI O NAL R A N GE S & B AC KG UARDS — RDV3-304, RIV3-304 BGRV2-1230, BGRV2-3030, BGRV3-3030H models PLANNING GUIDE
CONTENTS 30" Professional Range PAGE RDV3-304, RIV3-304 in mm Key Design Decisions 5 17 Ventilation Requirements 6 18 Product & Cavity Dimensions 7 19 Clearance Dimensions 8 20 Cavity Preparation 9 21 Product & Cavity Dimensions 10 22 Clearance Dimensions 11 23 Cavity Preparation 12 24 30" Professional Range RDV3-304-N, RDV3-304-L 30" Professional Range RIV3-304
CONTENTS (continued) 30" Professional Range Backguard BGRV2-1230 PAGE in mm Product Dimensions 9 18 Product Dimensions 10 19 30" Professional Range Backguard BGRV3-3030H in mm Product Dimensions 11 20 30" Professional Range Backguard BGRV2-3030
IMPERIAL
1 2 3 INSTALL TYPE REAR SURFACE BACKGUARD OPTIONS KEY DESIGN DECISIONS 30" Professional Range Model no: RDV3-304, RIV3-304 BGRV3-3030H ANGLED TRIM (Supplied with backguard) BGRV2-1230 MIN 6" CLEARANCE WALL COMBUSTIBLE NO BACKGUARD LOW THIN BACKGUARD HIGH THICK BACKGUARD WITH ANGLED TRIM BGRV2-3030 CUSTOM BACKGUARD* MIN 30" MAX 1/2" NON COMBUSTIBLE ISLAND CUSTOM FABRICATED* BACKGUARD HIGH THIN BACKGUARD *Fabricated from non combustible materials only. DATE: 14.07.
VENTILATION REQUIREMENTS 30" Professional Range 1 2 INSTALL TYPE HOOD SURROUND MATERIAL Model no: RDV3-304, RIV3-304 Specifications Ventilation Unit MIN 19" MIN 19" Hood Blower Ventilation Unit Hood MIN 30" MAX 42"* MIN 36" Blower Wall Installation Minumum 19'' Deep x Unit Width Minimum 550 CFM Island Installation Minumum 19'' Deep x Unit Width Minimum 550 CFM Note: A suitable hood must be installed above the range.
PRODUCT & CAVITY DIMENSIONS 30" Professional Range - Dual Fuel B 29 7/8" Model no: RDV3-304 H Product Dimensions in a Height of range (from floor to cooktop, excluding grates and rear trim) c 29 1/8" min 35 3/4" max 36 3/4" B Overall width of range CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL 29 7/8" c Overall depth of range (excluding handle and dials) 29 1/8" d Depth from rear of chassis to cabinetry face - projecting 25 3/8" e Depth from rear of chassis to cabinetry face - f
CLEARANCE DIMENSIONS 30" Professional Range - Dual Fuel C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C F Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE RDV3-304 D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE a Minimum width of ventilation hood installed above range - not shown* CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL E MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY D MINIMUM CLEARANCE: VENTILATIO
CAVITY PREPARATION 30" Professional Range - Dual Fuel Model no: RDV3-304 Specifications Oven Total Capacity 4 cu.ft Electrical Supply 120/240 VAC, 60Hz Service 30 amp circuit Max Current Draw Receptacle LEFT SIDE OF CAVITY 27 A 4-prong grounding type [NEMA 14-50P plug] Gas Natural Gas 6" to 9" W.C LP Propane 11" to 14" W.C Types REGULATOR* FINAL POSITION OF RANGE AGAINST WALL Connection 1/2” NPT Minimum 5/8” dia. flex line *Regulator location may vary depending on model.
PRODUCT & CAVITY DIMENSIONS 30" Professional Range - Induction B 29 7/8" Model no: RIV3-304 g Product Dimensions c 29 1/8" a Height of range (from floor to cooktop, excluding grates and rear trim) B Overall width of range CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL t o 29 1/8" d Depth from rear of chassis to cabinetry face - projecting 25 3/8" 1 3/4" g Depth of rear trim 2 7/8" h Height from countertop to bottom of control panel 7 3/4" j Height from countertop to centre of h
CLEARANCE DIMENSIONS 30" Professional Range - Induction C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE RIV3-304 D MINIMUM CLEARANCE: COMBUSTIBLE SURFACE a Minimum width of ventilation hood installed above range - not shown* CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL E MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY D MINIMUM CLEARANCE: VENTILATION
CAVITY PREPARATION 30" Professional Range - Induction Model no: RIV3-304 Specifications Oven Total Capacity 4 cu.ft Electrical Supply 120/240 VAC, 60Hz Service 50 amp circuit Max Current Draw LEFT SIDE OF CAVITY Receptacle IMPORTANT NOTE: For full installation and connection details please refer to our installation manual.
PRODUCT DIMENSIONS 30" Professional Range Backguard NOT TO SCALE BGRV2-1230 Model no: BGRV2-1230 Product Dimensions A Height of backguard above vent trim on range c 29 7/8'' B Overall height of backguard 15 15/16'' C Overall width of backguard 29 7/8'' D Overall depth of backguard DATUM : BACK OF PRODUCT in 10 3/8'' 1/2'' E Height of backguard below vent trim on range 5 9/16'' F Depth of backguard below vent trim on range 1/16'' PLAN VIEW RDV3-304 (illustrated) DATUM : BACK OF PRODUCT d 1/
PRODUCT DIMENSIONS 30" Professional Range Backguard c 29 7/8" NOT TO SCALE BGRV2-3030 Model no: DATUM : BACK OF PRODUCT BGRV2-3030 Product Dimensions d f A Height of backguard above vent trim on range B Overall height of backguard 29 1/8" C Overall width of backguard 29 7/8" D Overall depth of backguard and racks 9 5/16" E Depth of backguard F Depth of racks G Width of racks H Distance from top of backguard to bottom of racks g RDV3-304 (illustrated) I Distance from bottom of backguard to bo
NOT TO SCALE PRODUCT DIMENSIONS 30" Professional Range Backguard with Angled Vent Trim B 29 7/8'' BGRV3-3030H Model no: DATUM : BACK OF BACKGUARD BGRV3-3030H f Product Dimensions A Overall height of backguard with angled vent trim c h RDV3-304 (illustrated) DATUM : BACK OF BACKGUARD in 30'' B Overall width of backguard 29 7/8'' C Overall depth of backguard and racks 10 3/8'' D Height of backguard 26 1/2'' E Height of angled vent trim 3 1/2'' F Depth of angled vent trim 2 7/8'' G Depth o
METRIC
1 2 3 INSTALL TYPE REAR SURFACE BACKGUARD OPTIONS KEY DESIGN DECISIONS 30" Professional Range Model no: RDV3-304, RIV3-304 BGRV3-3030H ANGLED TRIM (Supplied with backguard) BGRV2-1230 MIN 152mm CLEARANCE WALL COMBUSTIBLE NO BACKGUARD LOW THIN BACKGUARD CUSTOM BACKGUARD* HIGH THICK BACKGUARD WITH ANGLED TRIM BGRV2-3030 MIN 762mm MAX 13mm NON COMBUSTIBLE ISLAND CUSTOM FABRICATED* BACKGUARD HIGH THIN BACKGUARD *Fabricated from non combustible materials only. DATE: 14.07.
VENTILATION REQUIREMENTS 30" Professional Range 1 2 INSTALL TYPE HOOD SURROUND MATERIAL Model no: RDV3-304, RIV3-304 Specifications Ventilation Unit MIN 480mm MIN 480mm Hood Blower Ventilation Unit MIN 762mm MAX 1067mm* Hood MIN 914mm Blower Wall Installation Minumum 480mm Deep x Unit Width Minimum 550 CFM Island Installation Minumum 480mm Deep x Unit Width Minimum 550 CFM Note: A suitable hood must be installed above the range.
PRODUCT & CAVITY DIMENSIONS 30" Professional Range - Dual Fuel B 759 Model no: RDV3-304 H Product Dimensions a Height of range (from floor to cooktop, excluding grates and rear trim) c 740 CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL u B Overall width of range 759 c Overall depth of range (excluding handle and dials) 740 d Depth from rear of chassis to cabinetry face - projecting 644 e Depth from rear of chassis to cabinetr
CLEARANCE DIMENSIONS 30" Professional Range - Dual Fuel C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C F Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE RDV3-304 D CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL MINIMUM CLEARANCE: COMBUSTIBLE SURFACE E MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY D MINIMUM CLEARANCE: VENTILATION HOOD D MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFACE PLAN VIEW Cleara
CAVITY PREPARATION 30" Professional Range - Dual Fuel Model no: RDV3-304 Specifications Oven Total Capacity 113L Electrical Supply 120/240 VAC, 60Hz Service 30 amp circuit Max Current Draw LEFT SIDE OF CAVITY Receptacle 27 A 4-prong grounding type [NEMA 14-50P plug] Gas REGULATOR* Connection 38mm Natural Gas 6" to 9" W.C LP Propane 11" to 14" W.C Types FINAL POSITION OF RANGE AGAINST WALL 38mm 1/2” NPT Minimum 5/8” dia. flex line *Regulator location may vary depending on model.
PRODUCT & CAVITY DIMENSIONS 30" Professional Range - Induction B 759 Model no: RIV3-304 g Product Dimensions c 740 a Height of range (from floor to cooktop, excluding grates and rear trim) CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL B Overall width of range 759 c Overall depth of range (excluding handle and dials) 740 d Depth from rear of chassis to cabinetry face - projecting 644 e Depth from rear of chassis to cabinetry f
CLEARANCE DIMENSIONS 30" Professional Range - Induction C MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE C Model no: MINIMUM CLEARANCE: NEAREST VERTICAL COMBUSTIBLE SURFACE RIV3-304 D CABINET FACE FOR INSTALLATION WITH PROJECTING CONTROL PANEL CABINET FACE FOR INSTALLATION WITH FLUSH CONTROL PANEL MINIMUM CLEARANCE: COMBUSTIBLE SURFACE E MAXIMUM OVERALL DEPTH OF OVERHEAD CABINETRY D MINIMUM CLEARANCE: VENTILATION HOOD D MINIMUM CLEARANCE: NON-COMBUSTIBLE SURFACE PLAN VIEW Clearanc
CAVITY PREPARATION 30" Professional Range - Induction Model no: RIV3-304 Specifications Oven Total Capacity 113L Electrical Supply 120/240 VAC, 60Hz Service 50 amp circuit Max Current Draw LEFT SIDE OF CAVITY Receptacle IMPORTANT NOTE: For full installation and connection details please refer to our installation manual.
PRODUCT DIMENSIONS 30" Professional Range Backguard NOT TO SCALE BGRV2-1230 Model no: BGRV2-1230 Product Dimensions c 759 263 B Overall height of backguard 405 C Overall width of backguard 759 D Overall depth of backguard DATUM : BACK OF PRODUCT mm A Height of backguard above vent trim on range 13 E Height of backguard below vent trim on range 142 F Depth of backguard below vent trim on range 1 PLAN VIEW RDV3-304 (illustrated) DATUM : BACK OF PRODUCT d 13 c 759 A 263 b DATUM : TOP OF
PRODUCT DIMENSIONS 30" Professional Range Backguard c 759 NOT TO SCALE BGRV2-3030 Model no: DATUM : BACK OF PRODUCT BGRV2-3030 Product Dimensions d f 720 B Overall height of backguard 740 C Overall width of backguard 759 D Overall depth of backguard and racks 237 E Depth of backguard F Depth of racks G Width of racks g RDV3-304 (illustrated) PLAN VIEW DATUM : BACK OF PRODUCT c 759 e mm A Height of backguard above vent trim on range 13 224 711 H Distance from top of backguard to bottom
PRODUCT DIMENSIONS 30" Professional Range Backguard with Angled Vent Trim B 759 NOT TO SCALE BGRV3-3030H Model no: DATUM : BACK OF BACKGUARD BGRV3-3030H f Product Dimensions c 264 h 763 B Overall width of backguard 759 C Overall depth of backguard and racks 264 D Height of backguard 673 E Height of angled vent trim RDV3-304 (illustrated) DATUM : BACK OF BACKGUARD mm A Overall height of backguard with angled vent trim 90 F Depth of angled vent trim 72 G Depth of backguard 33 i H Dep
IMPORTANT: The product dimensions and specifications apply at the date of issue. Under our policy of continuous product improvement, these dimensions and specifications may change at any time. Dimensions may vary by ±2mm (1/16"). Please read the installation guide for detailed information on installing the product or visit fisherpaykel.com.