VENTILATION REQUIREMENTS
A suitable ventilation hood must be installed above the range.
Installation recommendatons
VENTILATION UNIT STANDARD WALL INSTALLATION ISLAND INSTALLATION
Hood min 19" (480 mm) deep x unit width min 19” (480 mm) deep x unit width
Blower 48" Range min 1100 CFM min 1100 CFM
36" Range min 550 CFM min 550 CFM
30" Range min 550 CFM min 550 CFM
IMPORTANT
zz
Ventilation hoods and blowers are designed for use with single wall ducting. However, some local building codes or inspectors may require double wall ducting and/or a damper.
Consultlocal building codes and/or local agencies, before starting, to ensure that hood and duct installation will meet local requirements.
zz
Hood blower speeds should be variable to reduce noise and loss of heated or air conditioned household air when maximum ventilation is not required. Normally, the maximum blower
speed is only required when using the grill or the self-cleaning cycle.
zz
For best smoke elimination, the lower edge of the hood should be installed a minimum of 30" (762mm) to a recommended maximum of 42" (1067mm) above the range cooking surface. If
the hood contains any combustible materials (eg a wood covering) it must be a minimum of 36" (914mm) above the cooking surface.
zz
Due to a high volume of ventilation air, a source of make-up air (outside replacement air) is recommended. This is particularly important for tightly sealed and insulated homes. A
reputable heating and ventilating contractor should be consulted.
Wall Installation Island Installation
min 30"
(762mm)
max* 42"
(1067mm)
min 30"
(762mm)
max* 42"
(1067mm)
Hood
(non-combustible)
Hood
(inc. combustible,
eg a wood surround)
Hood
(non-combustible)
Hood
(inc. combustible,
eg a wood surround)
min 36"
(914mm)
min 36"
(914mm)
min 19" (480mm)
min 19" (480mm)
min 19" (480mm)
min 19" (480mm)
*Recommended maximum.