Installation Guide
Table Of Contents
- 1 Safety and warnings
- 2 Integrated columns
- 3 Components
- 4 tools
- 5 dual install options
- 6 appliance dimensions and specifications
- 7 Cabinetry options
- 8 Cavity dimensions
- 9 Door and toe kick panel dimensions
- !0 Custom door panel dimensions
- !1 Door clearance
- !2 Electrical and plumbing dimensions
- !3-A Electrical and plumbing specifications (FOR NZ & AU only)
- !3-b Electrical and plumbing specifications (for GB & EU only)
- !4 Before installation
- !5 cavity preparation
- !6-A water and power supply connection (For NZ & AU only)
- !6-b water and power supply connection (For GB & EU only)
- !7 Single installation
- !8 Dual installation
- !9 water filter InstallATION
- @0 door panel installation (Stainless steel)
- @1 door panel installation (Custom)
- @2 toe kick installation
- @3 cabinet trims Installation
- @4 door trims installation
- @5 Optional — Changing over door hinges
- @6 Final checklist
15
!1 DOOR CLEARANCE
RS46 RS61 RS76
DOOR CLEARANCE DIMENSIONS mm mm mm
A
Depth of door (90° open) measured from front of door 508 660 813
b
Minimum door clearance* to adjacent wall** (115° — full internal access) 292 356 419
c
Minimum door clearance* to adjacent wall** (90° — reduced internal access) 110 110 110
* Measured from front cabinetry edge.
** Does not include the Custom door panels or handles to be manufactured and fitted by a cabinetmaker.
For 90° door swing a hinge limiting bolt is supplied with your appliance.
This pin fits in the boreholes of the top hinge (Z).
WARNING!
●●
Before opening the doors, ensure that the appliance is stable.
●●
Follow these steps to avoid risks that can cause serious injury or death.
1 Open door to 90°.
2 Align the hinge limiting bolt vertically with the bore hole.
3 Insert the pin through the bore hole. Use a hammer to drive the pin
through the hole.
115° DOOR OPENING
(FULL INTERNAL ACCESS)
90° DOOR OPENING
B
AA
C
Wall Wall
Z