Installation Guide
Table Of Contents
- 1 Safety and warnings
- 2 Integrated columns
- 3 Components
- 4 tools
- 5 dual install options
- 6 appliance dimensions and specifications
- 7 Cabinetry options
- 8 Cavity dimensions
- 9 Door and toe kick panel dimensions
- !0 Custom door panel dimensions
- !1 Door clearance
- !2 Electrical and plumbing dimensions
- !3-A Electrical and plumbing specifications (FOR NZ & AU only)
- !3-b Electrical and plumbing specifications (for GB & EU only)
- !4 Before installation
- !5 cavity preparation
- !6-A water and power supply connection (For NZ & AU only)
- !6-b water and power supply connection (For GB & EU only)
- !7 Single installation
- !8 Dual installation
- !9 water filter InstallATION
- @0 door panel installation (Stainless steel)
- @1 door panel installation (Custom)
- @2 toe kick installation
- @3 cabinet trims Installation
- @4 door trims installation
- @5 Optional — Changing over door hinges
- @6 Final checklist
21
!5 CAVITY PREPARATION
min 180mm
E
Bracket
Appliance Wall
F
Bracket
Spacer
min 180mm
Wall
Appliance
2 Mark the screw locations of the anti-tip bracket on the wall based
on the most central wall stud (B).
– If there are no wall studs, the bracket can be installed to solid
brick walls with masonry plugs. (It is not recommended for
use with perforated brick or hollow concrete bricks).
3 Drill screw holes to the marked locations.
4 For wooden/plaster board wall installation: Skip to step 5.
For solid wall installation: Hammer 10x30mm masonry plugs (4x)
into the wall until flush.
5 Fix the bracket to the wall with 10-12x35mm pan head screws (4x),
and screw tightly (C).
A
Projection must be from the
alcove return towards the
bottom of the bracket
Bracket
SINGLE INSTALL DUAL INSTALL
C
B
Wall
board
Wall
stud
Anti-tip bracket
assembly kit
Anti-tip bracket
(1)
Masonry plug
(4)
#10x40
Pan Head
Philips Screw
#10x40
Pan Head
Philips Screw
#10x40 cross-head screw
(4)
Tools
Cross-head screwdriver
Powered driver
Pencil
Leveler
Safety glasses
Attaching the anti-tip bracket
1 Project horizontally from the bottom end of the alcove return
towards the back wall (A).
– This will locate the contact surface between the bracket
and the appliance.
IMPORTANT!
Make sure the bracket overlaps the
appliance by a minimum 180mm
for a secure hold (E).
IMPORTANT!
●●
Ensure the door of the appliance is closed when rolling into
the cabinetry.
●●
DO NOT attempt to open the door until the appliance is fully
installed. The anti-tip bracket and fittings supplied must be fitted
to the wall of the finished enclosure to withstand a 100kg load.
●●
Ensure that the anti-tip bracket is installed correctly to prevent the
possibility of the appliance tipping forward when the door is open.
WARNING!
Read the following reminders before fastening with masonry plugs and/or
screws to avoid serious injury or possible death:
●●
Ensure the screws avoid electrical, gas and water conduits.
●●
Ensure that the surface where the bracket is fastened can withstand a 100kg load.
●●
Ensure light-weight masonry material such as cinder block and new concrete
(no curing time) are not used in installation.
●●
Do not use metallic materials that may corrode, stain and/or damage the enclosure.
If the minimum 180mm overlap cannot
be achieved, install a solid spacer to
the wall stud behind the bracket (F).