Installation Guide

21
!5 CAVITY PREPARATION
min 180mm
E
Bracket
Appliance Wall
F
Bracket
Spacer
min 180mm
Wall
Appliance
2 Mark the screw locations of the anti-tip bracket on the wall based
on the most central wall stud (B).
If there are no wall studs, the bracket can be installed to solid
brick walls with masonry plugs. (It is not recommended for
use with perforated brick or hollow concrete bricks).
3 Drill screw holes to the marked locations.
4 For wooden/plaster board wall installation: Skip to step 5.
For solid wall installation: Hammer 10x30mm masonry plugs (4x)
into the wall until flush.
5 Fix the bracket to the wall with 10-12x35mm pan head screws (4x),
and screw tightly (C).
A
Projection must be from the
alcove return towards the
bottom of the bracket
Bracket
SINGLE INSTALL DUAL INSTALL
C
B
Wall
board
Wall
stud
Anti-tip bracket
assembly kit
Anti-tip bracket
(1)
Masonry plug
(4)
#10x40
Pan Head
Philips Screw
#10x40
Pan Head
Philips Screw
#10x40 cross-head screw
(4)
Tools
Cross-head screwdriver
Powered driver
Pencil
Leveler
Safety glasses
Attaching the anti-tip bracket
1 Project horizontally from the bottom end of the alcove return
towards the back wall (A).
This will locate the contact surface between the bracket
and the appliance.
IMPORTANT!
Make sure the bracket overlaps the
appliance by a minimum 180mm
for a secure hold (E).
IMPORTANT!
Ensure the door of the appliance is closed when rolling into
the cabinetry.
DO NOT attempt to open the door until the appliance is fully
installed. The anti-tip bracket and fittings supplied must be fitted
to the wall of the finished enclosure to withstand a 100kg load.
Ensure that the anti-tip bracket is installed correctly to prevent the
possibility of the appliance tipping forward when the door is open.
WARNING!
Read the following reminders before fastening with masonry plugs and/or
screws to avoid serious injury or possible death:
Ensure the screws avoid electrical, gas and water conduits.
Ensure that the surface where the bracket is fastened can withstand a 100kg load.
Ensure light-weight masonry material such as cinder block and new concrete
(no curing time) are not used in installation.
Do not use metallic materials that may corrode, stain and/or damage the enclosure.
If the minimum 180mm overlap cannot
be achieved, install a solid spacer to
the wall stud behind the bracket (F).