VACUUM SEAL DRAWER MINIMAL VB24SDEB1 & VB30SDEB1 CONTEMPORARY VB24SDEX1 & VB30SDEX1 PROFESSIONAL VB30SPEX1 INSTALLATION GUIDE US CA
CONTENTS Safety and warnings 4 Vacuum seal drawer models 5 Unpack your product 6 Electrical specifications 6 Parts supplied 7 Tools required 7 Product dimensions - 24" minimal & contemporary models 8 Product dimensions - 30" minimal & contemporary models Product dimensions - 30" professional models 9 10 Cabinetry dimensions - 24" minimal & contemporary models 11 Cabinetry dimensions - 30" minimal & contemporary models 12 Cabinetry dimensions - 30" professional model 13 Installation opt
SAFETY AND WARNINGS ! WARNING! Tip Hazard This product may tip. Keep children away and take care. Failure to follow this advice may result in injury. • Drawer must be secured in place by supplied screws. • Ensure there is a fixed shelf directly above the drawer if it is not installed under another product. ! WARNING! Cut Hazard Failure to use caution could result in injury. • Take care: some edges may be sharp. • Do not put fingers in the drawer when closing.
SAFETY AND WARNINGS VACUUM SEAL DRAWER MODELS READ AND SAVE THIS GUIDE To reduce the risk of fire, injury to persons or damage when using the appliance, follow the important safety guides listed below. Read all the instructions before using the appliance. Installation z z z z z z z z Please make this information available to the person installing the product.
UNPACK YOUR PRODUCT ELECTRICAL SPECIFICATIONS Remove the Vacuum Seal Drawer and accessories box from the packaging. Recycle the materials that can be reused. Dispose packaging materials in accordance with local regulations on waste disposal. Inspect the Vacuum Seal Drawer for any signs of damage. Do not install the Vacuum Seal Drawer if it has been damaged. If the product is damaged, contact your local Fisher & Paykel dealer.
PARTS SUPPLIED TOOLS REQUIRED VACUUM SEAL DRAWER MINIMAL VB24SDEB & VB30SDEB VACUUM SEAL DRAWER CONTEMPORARY VB24SDEX & VB30SDEX PROFESSIONAL VB30SPEX MINIMAL VB24SDEB & VB30SDEB CONTEMPORARY VB24SDEX & VB30SDEX SERVICE & WARRANTY PROFESSIONAL VB30SPEX SERVICE ET GARANTIE ΣΈΡΒΙΣ ΚΑΙ ΕΓΓΎΗΣΗ SERVIZIO E GARANZIA SERVICE & GARANTIE HUOLTO JA TAKUU SERVICE OG GARANTI 保修和维修 USER GUIDE US CA INSTALLATION GUIDE 服務和保修 US CA Service & Warranty (1) User guide (1) Installation guide (1) T20 star head
PRODUCT DIMENSIONS - 24" MINIMAL & CONTEMPORARY MODELS E PRODUCT DIMENSIONS IN MM 5 1/2 140 B Overall width of drawer 23 7/16 596 C Overall depth of drawer* 22 1/4 566 5 1/2 140 E Width of chassis** 21 7/8 556 F Depth of chassis*** 21 1/2 546 G Height of drawer front panel 5 3/8 136 H Depth of drawer front panel and flange 13/16 20 16 5/16 414 1/16 2 15 1/8 384 A Overall height of drawer C D Height of chassis H I ISOMETRIC I Depth of open drawer J Height from bottom of ch
PRODUCT DIMENSIONS - 30" MINIMAL & CONTEMPORARY MODELS E VB30SD PRODUCT DIMENSIONS c IN MM A Overall height of drawer 10 11/16 271 B Overall width of drawer 29 15/16 761 22 1/2 572 10 11/16 271 E Width of chassis** 28 3/8 720 F Depth of chassis*** 21 3/4 552 G Height of drawer front panel 10 1/2 267 H Depth of drawer front panel and flange 13/16 20 I Depth of open drawer 16 1/2 419 1/16 2 16 5/16 415 C Overall depth of drawer* D Height of chassis H I J Height from botto
PRODUCT DIMENSIONS - 30" PROFESSIONAL MODELS e PRODUCT DIMENSIONS c IN MM A Overall height of drawer 10 11/16 271 B Overall width of drawer 29 15/16 761 22 1/2 572 10 11/16 271 E Width of chassis** 28 3/8 720 F Depth of chassis*** 21 3/4 552 G Height of drawer front panel 10 1/2 267 H Depth of drawer front panel and flange 13/16 20 I Depth of open drawer 16 1/2 419 1/16 2 K Width of handle 29 736 L Depth of handle 2 1/4 58 16 5/16 415 C Overall depth of drawer* D Heig
CABINETRY DIMENSIONS - 24" MINIMAL & CONTEMPORARY MODELS FLUSH INSTALL d b PO* e a PO* c 13/16 (20mm)* f PROFILE PLAN PROUD INSTALL CABINETRY DIMENSIONS VB24SD INCHES MM A Minimum inside height of cavity 5 9/16 142 B Minimum inside width of cavity 22 1/16 560 C Minimum inside depth of cavity 22 1/16 560 D Overall width of cabinetry 23 5/8 600 1/8 3 1/16 2 E Minimum clearance between top of front panel and upper cabinetry panel F Minimum clearance between bottom of front panel an
CABINETRY DIMENSIONS - 30" MINIMAL & CONTEMPORARY MODELS FLUSH INSTALL d b *PO e *PO a c 13/16 (20mm)* f PLAN PROFILE PROUD INSTALL CABINETRY DIMENSIONS VB30SD INCHES MM A Minimum inside height of cavity 10 3/4 273 B Minimum inside width of cavity 28 1/2 724 C Minimum inside depth of cavity 22 1/16 560 D Overall width of cabinetry 30 762 E Minimum clearance between top of front panel and upper cabinetry panel 1/8 3 1/16 2 F Minimum clearance between bottom of front panel and lowe
CABINETRY DIMENSIONS - 30" PROFESSIONAL MODEL d FLUSH INSTALL b *PO e *PO c 13/16 (20mm)* a f PROFILE CABINETRY DIMENSIONS PLAN VB30P INCHES MM A Minimum inside height of cavity 10 3/4 273 B Minimum inside width of cavity 28 1/2 724 C Minimum inside depth of cavity 22 1/16 560 D Overall width of cabinetry 30 762 E Minimum clearance between top of front panel and upper cabinetry panel 1/8 3 1/16 2 F Minimum clearance between bottom of front panel and lower cabinetry panel PROUD
INSTALLATION OPTIONS STANDALONE INSTALLATION COMBINED WITH SINGLE OVEN COMBINED WITH COMPANION PRODUCT This installation is suitable for Minimal, Contemporary & Professional 24" and 30" Vacuum seal drawers. A fixed shelf must be provided above the drawer. This combination is suitable for 24" and 30" Vacuum seal drawers that can fully support 24" and 30" Fisher & Paykel wall ovens, respectively.
INSTALLATION OPTIONS COMBINED WITH DOUBLE OVEN COMBINED WITH SINGLE OVEN & COMPANION PRODUCT This combination is suitable for 30" Vacuum seal drawer that can fully support a 30" Fisher & Paykel double oven. This combination is suitable for 30" Vacuum seal drawer that can fully support both Fisher & Paykel 30" double oven and companion product. A shelf is required above the oven to support the companion product. Ensure the bottom shelf can fully support the weight of all appliances.
PRIOR TO INSTALLATION INSTALL THE AIR FILTER REMOVE THE TRANSIT SCREWS The transport screws must be removed before starting up for the first time to avoid damage to the drawer. power cable holder Unscrew the transport screws from under the power cable and holder. transport screws locking cap 1 Pull out the locking cap with pliers. 2 Insert the locking cap in the holder.
INSTALLING THE DRAWER 1 2 Connect the power plug into the power outlet. Slide the drawer carefully into the cabinetry. Push the drawer back into the cabinetry while ensuring the side brackets engages the anti-tip brackets. Align the front panel* with the cabinetry as desired. 3 Open the drawer and extend fully. 4 Secure the attachment flanges of the drawer to the side edges of cabinetry with 4x20 T20 star head countersunk screws. * Flush alignment illustrated.
ADJUSTING THE DEPTH Applicable for 30" Vacuum seal drawer only. The depth of the front panel of the drawer can be adjusted to align with the surrounding cabinetry. 1 18 The front panel of the drawer can be adjusted vertically to align with the surrounding cabinetry. Open the drawer fully. Using a hex key, turn the adjustment screw to move the front panel forward. Turn clockwise to move backwards or counterclockwise to move forwards.
INSTALLER CHECKLIST IMPORTANT! FP WARMER DRAWER INTERFACE LOGIC_V1 USER PRESSES ON/OFF BUTTON 1h Read all installation instructions in this manual to see if the unit has been correctly installed. Ensure that installation has been completed correctly before use.
FISHERPAYKEL.COM © Fisher & Paykel Appliances 2020. All rights reserved. The models shown in this guide may not be available in all markets and are subject to change at any time. The product specifications in this guide apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at any time.