- Sanyo Fisher Co. INSTRUCTIONS MANUAL Multiplexer MPX-CD163, MPX-CD93

VCR SET SETTINGS
VCR SET settings are for specifying how a unit to record images from a camera will carry out the recording.
VCR SET settings
Press the MENU button.
The MAIN MENU screen will be displayed.
Use the cursor button to select
VCR SET and then press the
NEXT button.
The VCR SET screen will be displayed.
Use the cursor button to select
RECORDER (example: TLS), and
press the setting buttons.
Use the setting buttons to switch the
recording unit.
MENU
1
(MAIN MENU)
1 LANGUAGE *
2 CLOCK SET *
3 DISPLAY SET *
4 VCR SET *
5 ALARM SET *
6 SECURITY SET *
7 CONTROL SET *
8 ALARM DATA *
(*:NEXT)
NEXT
2
(VCR SET)
RECORDER TLS
REC.SPEED 2 H
ALARM REC.SPEED 2 H
SW.IN EDGE ñ
REC.PICTURE 01
PROGRAM REC. OFF
+
3
When a real time VCR
is selected
(VCR SET)
RECORDER REAL
REC.SPEED 6 H
ALARM REC.SPEED 6 H
When a digital video
recorder is selected
When a time lapse VCR
is selected
(VCR SET)
RECORDER TLS
REC.SPEED 2 H
ALARM REC.SPEED 2 H
(VCR SET)
RECORDER DVR
REC.SPEED 0.02 S
ALARM REC.SPEED 0.02 S
Switch (SW) wave pattern signal timing setting
If the recording unit has a SW signal output
connector
If a SW signal is output
A signal from the video output connector of this unit is
switched automatically to the recording speed and sent to
the recording unit, by means of a SW signal (recording
speed pulse signal) that has been specified by the
recording unit for which the speed for recording images
output from this unit has been selected. In cases such as
this there is no need to specify REC. SPEED and ALARM
REC. SPEED settings for this unit.
If a SW signal is not output
Even if there is a connection between the selected
recording unit (SW signal output connector) and this unit,
it sometimes happens that the SW signal is not output
only in the case of 3-hour and 6-hour video recording
speeds. In cases such as this, the REC. SPEED and
ALARM REC. SPEED settings for this unit must be
specified. (VCR only)
If the recording unit does not have a SW
signal output connector
Match REC. SPEED and ALARM REC. SPEED of this unit to
the recording speed of the recording unit that is connected.
Settings are not required for a digital video recorder.
VCR SET-1
VCR SET-1
English
53