Product Specifications

27
WIRING DIAGRAM FOR GAS RANGES
WITH ELECTRICAL EQUIPMENT
GROUND NOTICE
WARNING:
FRAME GROUNDED TO NEUTRAL OF APPLIANCE THROUGH A LINK. IF USED IN A MOBILE HOME
OR IF LOCAL CODES DO NOT PERMIT GROUNDING THROUGH THE NEUTRAL, DISCONNECT THE LINK FROM
THE NEUTRAL AND USE GROUNDING TERMINAL OR LEAD TO GROUND UNIT IN ACCORDANCE WITH LOCAL
CODES. CONNECT NEUTRAL TERMINAL OR LEAD TO BRANCH CIRCUIT NEUTRAL IN USUAL MANNER.
CONSULT MANUFACTURER’S INSTRUCTIONS WHEN CODES REQUIRE THAT 3-CONDUCTOR CORD
ASSEMBLIES MUST BE REPLACED BY 4-CONDUCTOR CORD ASSEMBLIES.
SEE RA
TING PLATE FOR TOTAL WATTAGE AND VOLTAGE
USE ONLY COPPER OR ALUMINUM CONDUCTORS SEE INSTALLATION INSTRUCTIONS
525 188-6C049 REV. 0
WIRING DIAGRAM FOR 48'' SELF CLEAN 188-6C049
MODEL NO. 525
‘WARNING’
THIS APPLIANCE MUST BE CONNECTED AS SHOWN IN FIGURE 1, OR 2. IF A CORD IS
UTILIZED IT MUST BE RATED AT 250 VOLTS 40 AMPERES AND CERTIFIED FOR USE ON
HOUSEHOLD RANGES.
FIG. 1
FIG. 2
WIRING RANGE CONNECTION CORD
(FOR DUAL-FUEL RANGES ONLY)
BLACK
WHITE
RED
GROUND LINK
STRAIN RELIEF
STANDARD 120/240V HOOKUP
FRAME GROUNDED TO NEUTRAL
THROUGH
A LINK
BLACK
WHITE
RED
BLACK
WHITE
RED
GREEN
STRAIN RELIEF
ST
ANDARD 120/240V HOOKUP
WHERE SEPARATE GROUND IS REQUIRED