Product Manual

- 5 -
PRESSURES: MAXIMUM INLET PRESSURES: LP: 14.0 IN. WC.
NG: 14.0 IN. WC.
MINIMUM INLET PRESSURES: LP: 11.0 IN. WC.
NG: 9.0 IN. WC.
This heater must be supplied by pressures indicated on the
approval label. Over pressure may cause controls to fail.
DO NOT supply this unit with more than ½ psig (14.0 in. W.C.)
Note: A second stage regulator must be installed if the supply
pressure exceeds ½ psig.
FUEL: This heater will operate on propane or natural gas. The manifold
pressures are listed on the approval label. Ensure that the proper
pressure settings are achieved depending on the fuel being used.
A fuel selector valve is located on the manifold of the heater.
Ensure that this valve is in the proper position depending on the
fuel being used. DO NOT operate the heater with the valve in the
incorrect position.
HOSES: All hoses used to connect this heater of fuel supply must be Type 1
approved propane / natural gas hose assemblies.
ELECTRICAL: WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for
your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle.
120v supply must be available. Please note that the motor on this
unit requires 20 amps. Ensure appropriate gauge extension cord is
used.