PRESSURES: MAXIMUM INLET PRESSURES: LP: 13.0 IN. WC.
NG: 10.0 IN. WC.
MINIMUM INLET PRESSURES: LP: 8.0 IN. WC.
NG: 7.0 IN. WC.
This heater must be supplied by pressures indicated on the approval
label. Over pressure may cause controls to fail.
DO NOT supply this unit with more than ½ psig (14.0 in. W.C.)
Note: A second stage regulator must be installed if the supply pressure
exceeds ½ psig.
FUEL: This heater will operate on propane OR natural gas NOT BOTH. The
manifold pressures are listed on the approval label. To determine which
fuel to use see rating plate. DO NOT attempt to use the heater without
consulting the rating plate.
Note: The proper main burner orifice must be installed and rating plate
must reflect the fuel the heater burning. DO NOT operate the heater
with out consulting the rating plate.
Heater conversion must be done by a qualified technician and rating
plate must reflect any change.
HOSES: All hoses used to connect this heater of fuel supply must be Type 1
approved propane / natural gas hose assemblies.
ELECTRICAL: WARNING
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged directly into a
properly grounded three-prong receptacle.
115v supply must be available. Please note that the heater requires 15
amps for proper operation. Ensure appropriate gauge extension cord is
used.
• 12/3 AWG at 50 Feet
• 10/3 AWG at 100 Feet