3 Maintainance via Web Interface
Most configuration can be done via the HUB web interface. First connect to the Wifi
Hotspot with the name like FLATMUAVW-xxxxxx (.e. FLATMUAVW-000042 when
the serial number is 42) and the given password. The default password is
“password”. Please make sure to change when configuring the device.
On the OEM variant with a U.FL connector instead of an PCB antenna, a WiFi
antenna needs to be connected. If not, the range might be insufficient for proper
operation of the Web Interface.
Open the address http://10.10.10.10 in a browser of the device that is connected
to the Hotspot. The Web Interface should now load. On the Status page, the
connectivity, system information and GNSS fix are shown.
3.1 Updating the Firmware
On the navigation bar of the page, go to “Maintenance”, “Firmware Update”. To
update the Atom with a new PowerFLARM Firmware, a .fw file is needed. To update
FLARM HUB, a .bin file is needed.
3.2 Port Configuration
The protocol and baudrate on the JST port can be configured on the Web Interface
in “Configuration”, “FLARM”, “Data Port”.