User Manual

Page 19
User Programming Mode
User Programming Mode Options
Abbreviation Parameter Description
DO Day Override The timer’s day override setting
RT Regeneration Time The time of day that the system
will regenerate (meter delayed,
timeclock, and day-of-week
systems)
H Feed Water Hardness The hardness of the inlet water -
used to calculate system capacity
for metered systems
RC Reserve Capacity The fixed reserve capacity
CD Current Day The current day of week
NOTES:
Some items may not be shown depending on timer configuration.
The timer will discard any changes and exit User Mode if any button is not pressed for sixty seconds.
User Programming Mode Steps
Press the Up and Down buttons for five seconds while in service, and the time of day is NOT set to 12:01 PM.1.
Use this display to adjust the Day Override. This option setting is identified by “DO” in the upper left hand 2.
corner of the screen.
Press the Extra Cycle button. Use this display to adjust the Regeneration Time. This option setting is identified 3.
by “RT” in the upper left hand corner of the screen.
Press the Extra Cycle button. Use this display to adjust the Feed Water Hardness. This option setting is 4.
identified by “H” in the upper left hand corner of the screen.
Range: 4-199 hardness