Interspace divert and merge module XBUT 180 C 5110813-01 5110815-01 User documentation ver 1.
Interspace divert and merge module XBUT 180 C Observe! The sensor set-up depends on pallet size.
Interspace divert and merge module XBUT 180 C Function description Return stop position The Interspace module is divided into Stop position and Return stop position. This function supports ”non-memory transports”.(see below) Stop position The RFID-reader of the Stop position identifies the pallet, which is necessary for deciding whether the pallet should go straight or go through the short-cut.
Interspace divert and merge module XBUT 180 C Initiators and actuators A2 B2 B4 A3 B6 B7 B3 B1 A1 B10 Initiators Actuators B1 Pre-stop B2 Occupied 1 B3 Occupied 2 B4 Occupied 3 B5 Return stop B6 Straight flow B7 Short-cut flow A1 Stop. Single acting. A2 Return stop. Single acting. A3 Arm. Double acting.
Interspace divert and merge module XBUT 180 C Interfaces Initiators B1: M12-connector, 3-pin B2: M12-connector, 3-pin B3: M12-connector, 3-pin B4: M12-connector, 3-pin B5: M12-connector, 3-pin B6: M12-connector, 3-pin B7: M12-connector, 3-pin B10: M12-connector, 4-pin (Asi) Note: Sensors placed inside the housing is equipped with sensor cables (with the given connector type above), reaching outside the housing.
Interspace divert and merge module XBUT 180 C Spare parts Standard Des.
Interspace divert and merge module XBUT 180 C Spare parts Standard Des.
Interspace divert and merge module XBUT 180 C Sensor details Sensor B1 ”Stop” Type: Proximity switch, inductive Position: Placed together with stop. Function: Detects the initiator plate of the pallet before the pallet is stopped and stays active until the pallet leaves the stop. The reason why the pallet is detected by the sensor before the pallet hits the stop, is to enchance the efficiency of the pallet flow.
Interspace divert and merge module XBUT 180 C Pneumatic drawing X85 Pallet