QR 6621440
X85 Pallet
Function description The Combine module gives the opportunity to split and merge two flows of pallets (highway to satellite / satellite to highway) in a fully controlled way. Stop positions The two flows are equipped with stops in order to avoid collisions.
Initiators and actuators B7 B1 A1 A3 B5 B6 B3 B4 A2 B2 Initiators Actuators B1 Pre-stop highway B2 Pre-stop satellite B3 Sensing pallet route B4 Sensing pallet route B5 Straight flow B6 Short-cut flow B7 RFID reader A1 Pre-stop. Single acting. A2 Pre-stop. Single acting. A3 Arm. Double acting.
Interfaces Initiators B1: M12-connector, 3-pin B2: M12-connector, 3-pin B3: M12-connector, 3-pin B4: M12-connector, 3-pin B5: M12-connector, 3-pin B6: M12-connector, 3-pin B7: M12-connector, 4-pin (Asi) Actuators Pneumatic cylinders A1: 6 mm A2: 6 mm A3: 6 mm X85 Pallet
Spare parts Standard Des. Manufacturer Type nam e Sensor B1 Sensor bracket SICK FlexLink order no IM12-08NPS-ZC1 7900045 SICK IM12-08NPS-ZC1 7900045 SICK MHL 15-P3336 1026129 FlexLink Sensor B2 Sensor B3 Reflector FlexLink . Reflector IFM Sensor External order no B4 SICK Reflector FlexLink .
Cylinder details Cylinder A1 and A2 ”Pre-stop” Type: Single acting with two ports. Function: Pressurized: Releases the pallet flow No pressure: Blocks the pallet flow For safety reasons, the pallet stop is blocking the flow in case of a pressure drop, preventing pallets from travelling uncontrolled along the conveyor. The stop should not re-block the flow while a pallet puck is in a position where it could be clamped. It is recommended to re-block the flow after each pallet.
Sensor details Sensor B1 and B2 ”Pre-stop” Type: Proximity switch, inductive Position: Placed together with Pre-stop. Function: Detects the initiator plate of the pallet before the pallet is stopped and stays active until the pallet leaves the stop. The reason why the pallet is detected by the sensor before the pallet hits the stop, is to enhance the efficiency of the pallet flow. As the pallet is detected in advance, the controller has time to take a decision whether or not the pallet should be stopped.
Pneumatic drawing XBUT 45 CR, 90 CR, 45 CL and 90 CL Pallet pre-stop PUN-6x1 14 4 2 5 1 3 Arm Pallet pre-stop 12 PUN-6x1 14 4 2 5 1 3 12 14 PUN-6x1 4 2 5 1 3 12