Specification

TECHNICAL INFORMATION
F4601
Installation & Operating Instructions for the
Owner’s Installation ,Manual
WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER
THANK YOU FOR YOUR PURCHASE
SAFETY RULES
SKU Rated Voltage Light CCT.Rated power(motor).
110-120V AC
4000K
F4601WH
56W
110-120V AC
3000K
F4601Y
56W
110-120V AC
4000K
F4601
56W
110-120V AC
3000K
F4601BZ
56W
Thank you for purchasing this quality product. To ensure correct function and safety, please read and save all
instructions before using the product
1. Mounting Bracket x1
2. Canopy screws x 2
3. Canopy x 1
4. Downrod&hanger ball x 1
5. Bolt x 1
6. Coupling cover x 1
7. Pin x 1
8. Top housing x 1
9. Blades x 4
10. Fan motor assembly x 1
11. Base plate x 1
12. Lamp shade x 1
13. Light pan x 1
14. Wood screws x 2
15. Expansion screw x 2
16. Plastic anchor x 2
17. Balance tapes x 4
18. Remote control x 1set
19. Crystal chain x 61
20. Crystal bead x 61
BEFORE INSTALLATION
Unpack your fan and check the contents.You should have followings:
CAUTION
READ INSTRUCTIONS CAREFULLY FOR SAFE
INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT
A QUALIFIED ELECTRICIAN
INSTALLING THE FAN
Tools Required: Phillips screwdriver, Pair of pliers, straight slot screwdriver, adjustable wrench, step ladder, and wire cutters.
INSTALLLING THE MOUNTING BRACKET
The ceiling fan must be installed in a location so that the blades are 300mm spacing from the tip of the blade to the nearest objects or walls. When hanging the Fan REMEMBER to turn off the power..
Follow the instruction below to hang your fan properly:
1. For the concrete ceiling, drill two holes in the ceiling
NOTE:Hanger after the installation must be able to withstand the weight of 45kg or more
and secure the mounting bracket to the ceiling with two
Φ8 (distance between the two holes should be
appropriate) expansion screws, flat washers,nuts
provided and tighten with a spanner.
2. For the wood ceiling, Secure the mounting bracket to the
ceiling is capable of carrying a load of at least 45KGS with
two long mounting screws and washers provided. Be sure
at least 30mm of the screw is threaded into the support.
3. Refer to the Fig. in right for mounting when the ceiling is
angled max. 15 degree angle.
110-120V AC
4000K
F4601BK
56W
1.To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.
2. All wiring must be in accordance with the National Electrical Code and local electrical codes. Electrical installation should be
performed by a qualified licensed electrician.
3. WARNING: To reduce the risk of electrical shock and fire, do not use this fan with any solid-state fan speed control device.
4. WARNING: To reduce the risk of fire, electric shock, or personal injury, mount to outlet box marked "Acceptable for Fan Support of
45kg (99.12 lbs.) Or Less" and use mounting screws provided with the outlet box. Most outlet boxes commonly used for the support
of light fixtures are not acceptable for fan support and may need to be replaced. Due to the complexity of the installation of this fan, a
qualified licensed electrician is strongly recommended.
5. The outlet box and support structure must be securely mounted and capable of reliably supporting a minimum of 45KGS. Use only
UL Listed outlet boxes marked FOR FAN SUPPORT.
6. The fan must be mounted with a minimum of 7 feet clearance from the trailing edge of the blades to the floor.
7. Avoid placing objects in the path of the blades.
9. To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
10. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for
most cleaning.
11. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The
wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box.
12. Electrical diagrams are for reference only.
13. The fan is suitable for indoor use only.