DRIVE SPECIFICATIONS AND DIMENSIONS
Model Number AD052045 AD070059 AD096074 AD096096 AD150145
Input from power
source
Voltage 180 -264 AC (Single or Three Phase)
Frequency 50/60 Hz
Current (Max) - RMS
14.2 Amps 1ø
(6.7 Amps 3ø)
17.4 Amps 1ø
(8.7 Amps 3ø)
23.2 Amps 1ø
(11.9 Amps 3ø)
23.2 Amps 1ø
(11.9 Amps 3ø)
29.5 Amps 1ø
(15.7 Amps 3ø)
Power Factor 1.0 ( constant )
Output to Motor
(Three Phase )
Voltage Voltage Automatically Adjust with Frequency (0 thru 230 Volts)
Frequency Range 15 - 60 Hz
Current, Factory Programmed*
(RMS, Each Phase)
4.5 Amps 5.9 Amps 7.4 Amps 9.6 Amps 14.5 Amps
Current (Max)
(RMS, Each Phase)
5.2 Amps 7.0 Amps 9.6 Amps 9.6 Amps 15.0 Amps
For Use With
Motor Standard 60 Hz. Pump & 230 Volt 3 Phase Motor Combination
Reference HP Rating* 1 1.5 2 3 5
Pressure Setting
Factory preset 50 PSI
Adjustable Range 30 - 80 PSI
Operating
Conditions
Temperature
(@ 230 VAC input)
10° to 40° C ( 14° to 104° F. )
Relative Humidity Max 95% Non-condensing
Controller Size NEMA 1 ( indoor ) 10.47” H x 3.35” W x 6.15” D 12.54” H x 3.94” W x 6.90” D 15.60” x 4.48” x 8.05”
Weight 2.9 lbs. 3.1 lbs. 4.6 lbs. 4.6 lbs. 9.9 lbs.
RMS = ROOT MEAN SQUARED
* The electrical characteristics of motors vary slightly. See Amp draw on motor nameplate. If the maximum motor cur-
rent value (Amp draw) is more than 5% of the programmed value of the Drive, the Drive will need to be set to the
current value of the motor to provide proper protection..
0 1 2 3 4 5 6 7 8
6.0
5.0
4.0
3.0
2.0
1.0
0.0
Run Time (Min.)
Off Time (Min.)
IL0750
Figure 12
OVER-TEMPERATURE
The Artesian Drive controller is designed for full power opera-
tion in ambient temperatures up to 104°F (40°C) as long as
the input voltage is kept at 230 VAC. Under extreme thermal
conditions, the controller will reduce the switching frequency
in an attempt to avoid shutdown. If the temperature of the
controller is still too hot the controller will shut itself off to
avoid causing damage to itself. Full pump output is restored
when the controller temperature cools to a safe level.
NOTE: The Artesian Drives are factory programmed to
F&W pumps to provide optimum performance and motor
protection. The Artesian Drive can be used with other
pumps, but the maximum motor amperage needs to be
compared to the factory programmed current value (refer
to the Specifications section under the appropriate model).
If the maximum motor current varies more than 5% from
the programmed value, the motor current value in the drive
needs to be changed for motor protection and optimum
performance. For details on how to change this value in the
drive, please contact Technical Support at 1-800-345-9422.