® CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL MODEL #VP05, VP10 C US NSF/ANSI 372 255405 For loose, missing or damaged parts, or if the unit does not seem to be operating properly, please call before returning unit to the place of purchase. Phone No.
General Safety Information PUMP Safety Information Please read and understand this manual before attempting to assemble, operate or install this product. For questions, please call customer service at 1-800-742-5044 (7:30am - 5:00pm ESDT Mon. - Fri.) SHOCK HAZARD 1. Meet United States National Electrical Code and local codes for all wiring. Hazardous voltage. Can shock, burn or cause death. Ground pump before connecting to power supply. This is a SAFETY ALERT SYMBOL.
FIG 1 TYPICAL INSTALLATIONS Ball Valve #3 (Closed) By-Pass City Water Main only 1" Dia. Suction IN Ball Valve #1 (Open) Adjustable Pressure Regulator (APR) #1 Union Optional Water Tank Drain Home or Irrigation 1" Dia. Discharge OUT Adjustable Union Ball Pressure Valve Pressure Relief Regulator #2 Valve (APR) (Open) (PRV) #2 #3 IL1213 1/2 HP PERFORMANCE GENERAL PUMP INSTALLATION / SETUP (FIG 1) See charts below for expected system pressure at various incoming line pressure / flow rates.
nameplate data Model HP Volts HZ/Ph Amp Amb Class Rating PRIMING VP05 1/2 115 60/1 6.0 40C B Cont After installation (with the pump OFF), open ball valves #1 and #2, and slowly unthread the air relief plug (fig 2). Allow inlet water pressure to fill the pump cavity and remove in-line air pockets. After the pump cavity fills with water, retighten the air relief plug. VP10 1 115 60/1 11 40C B Cont FIG 2 PRIMING ILLUSTRATION a. Open ball valves #1 and #2, close 3.
Checking and Setting Tank PSI – Factory tank PSI settings are 26 PSI (1/2 hp) and 36 PSI (1 hp). If the inlet PSI is HIGHER than the factory settings, increase the tank PSI to be approximately 5 PSI higher than incoming pressure. To check the tank air pressure, turn off power, open a tap on the discharge line to release pressure from the pump, unscrew the black plastic cover and apply a pressure gauge to the valve as shown in Fig 3.
TROUBLESHOOTING Before ANY work with the pump, SHUT OFF the electrical supply and ball valves #1 and #2 to prevent electrical shock and water damage. Problem Pump does not start or shuts down, Cause No power supply. Incorrect voltage. Correction Connect the electricity supply. Pump is 115 Volt only. Incorrectly plumbed. Blocked inlet Insufficient water supply Pump starts when no water is consumed. Pipe leaking. Tank pressure is low. Air in the system.
Maintenance Requirements • • Pressure Tank Charge – should be checked every 3 months to confirm tank air pressure. See FIG 3 for description to check air pressure. Pump Suction Inlet Screen – if internal debris blocks or restricts the inlet suction screen (fig 5), manually clean with hands. FIG 5 – INLET SCREEN Note – tank pressure should be set approximately 5 psi higher than the expected incoming pressure.
Outline / Dimensional Size C 3.96 Outlet 7.74 1.77 NPT 1" Inlet NPT 1" 8.88 5.71 3.35 6.89 B 5.12 6.3 4-Ø0.4 A IL1212 DIMENSIONS CHART C Model A (in.) B (in.) C (in.) VP05 VP10 13.56 16.42 5.43 6.46 5.63 6.65 LIMITED WARRANTY THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE.