Quick Start Guide

QUICK REFERENCE GUIDE.
SEE INSTRUCTION MANUAL FOR
COMPLETE DETAILS.
BOOSTER PUMP
DO’S and
DON’TS
STOP
For loose, missing or damaged parts, or if the unit
does not seem to be operating properly, please call
before returning unit to the local sales branch.
TOLL FREE HELP LINE: 1-800-742-5044
Monday thru Friday - 7:30 am to 5:00 pm E.S.T.
See reverse side for more information.
DO NOT run pump dry or pump damage WILL
occur!
Pump only clean water. DO NOT pump water
which contains sand, mud, silt or debris.
DO NOT pump oil, petroleum products,
chemicals, cleaning agents or viscous
liquids.
DO NOT pump less than 1.5 gallons per minute
or damage will occur.
CAUTION: Improper installation may result in
personal injury, property damage or pump
failure. Read manual before installation or
operation.
DON’T . . .
024330 A
Pump and plumbing must be full of water
before startup
Install a pressure relief valve (PRV).
PRV settings will vary according to the
application.
Pressure
Gauge
Pressure
Relief
Valve
Pressure
Switch
Drain
Ground motor, but DO NOT ground to a gas
supply line.
GRD
Check voltage of power supply.
-
Wire motor to correct supply voltage.
- See motor nameplate and wiring
diagrams.
115/230 DUAL VOLTAGE MOTOR
L1
L2A B
L1
L2A B
IL0180
115 VOLT
SINGLE PHASE
LINE
230 VOLT
SINGLE PHASE
LINE
NOTE: This diagram does not apply to all models.
All valves and nozzles on both the inlet and
outlet side of the pump must be open
while the pump is in operation
Inlet
Gate/Ball Valve
(Normally Open)
Check Valve
Union
S p
Outlet
DO . . .