Manual

FT-12 Technical Manual, Rev. 1.35 November 2010
Page 38 of 44
Examples: The commands will be used for an indicator which instrument address is set to 1.
Reading weight data: @010300000002FA<Cr>
Reading status data: @010300020001F9<Cr>
Reading Tare data: @010300030002F7<Cr>
Taring: @011000080001020002E2<Cr>
Loading 1500 value to Setpoint 1:
1.step: @0110000B000204000005DCFD<Cr>
2.step: @011000080001020006DE<Cr>
Reading Setpoint 1 (SP1=1500):
1. step: @011000080001020007DD<Cr>
2. step: @0103000B0002EF<Cr>
Break down an example:
Setpoint 1: Write value 1500 into buffer
@ 01 10 000B 0002 04 000005DC FD <Cr>
STX Device-
Adresse
Write Add. Reg.
for
Setpoint 1
No. of
Addr. Reg.
No. of
Data Reg.
Value 1500 (dec.),
shown in hex
Checksum EOP
NOTE: The points you should paid attention to while loading and reading setpoints are:
 To write any value to FT-1x the value should be loaded into the buffer (address 000B). Afterwards send
command “6” to address 0008 to make FT-1x to use the value at address 000B.
 To read a value from FT-1x you should send command “7” to address 0008 to make FT-1x to load the
value into the buffer. Afterwards you can read the value at address 000B.
 The commands “6” and “7” which are sent to address 0008 let you write or read all setpoints