Junction Box Type KEK-4 TECHNICAL MANUAL Flintec GmbH Bemannsbruch 9 74909 Meckesheim GERMANY www.flintec.
RIGHTS AND LIABILITIES All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, mechanical, photocopying, recording, or otherwise, without the prior written permission of Flintec GmbH No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this book, FLINTEC assumes no responsibility for errors or omissions.
INTRODUCTION AND TECHNICAL DATA The stainless steel junction box is designed for the parallel connection of up to 4 load cells. Type KEK-4 No. of load cells up to 4 Housing size 105 x 210 x 40 mm Inputs 4x PG9 Output 1x PG9 The junction box type KEK can be connected to the instrumentation with a shielded 6-wire signal cable. The corner correction is done with resistors and/or potentiometer.
After all conductors have been clamped to the terminals, the cable glands must be tightened. Please verify that all cable glands are tight and the cable is fully stress relieved. OUTPUT CABLE CONNECTION The signal cable (connection between junction box and the following electronics) should be a 6 – wire shielded cable and has to be kept as short as possible. Depending on type and manufacturer signal cables may have different colours. Therefore make your own choice.