User's Manual

Table Of Contents
18.1 Typical moisture measurement and documentation
procedure
General
The following procedure can form the basis for other procedures using Extech meters
and infrared cameras.
Procedure
Follow this procedure:
Use the infrared camera to identify any potential damp areas behind walls
and ceilings.
1
Use the moisture meter to measure the moisture levels at various suspect
locations that may have been found.
2
When a spot of particular interest is located, store the moisture reading in
the moisture meter’s memory and identify the measurement spot with a
handprint or other thermal identifying marker.
3
Recall the reading from the meter memory. The moisture meter will now
continuously transmit this reading to the infrared camera.
4
Use the camera to take a thermal image of the area with the identifying
marker. The stored data from the moisture meter will also be saved on the
image.
5
52 Publ. No. T559597 Rev. a554 ENGLISH (EN) September 27, 2011
18 Fetching data from external Extech meters