User's Manual
Table Of Contents
- 1 Disclaimers
- 2 Safety information
- 3 Notice to user
- 4 Customer help
- 5 Quick Start Guide
- 6 List of accessories and services
- 7 Description
- 8 Operation
- 8.1 Charging the battery
- 8.2 Turning on and turning off the camera
- 8.3 Saving an image
- 8.4 Recalling an image
- 8.5 Deleting an image
- 8.6 Deleting all images
- 8.7 Measuring a temperature using a spotmeter
- 8.8 Measuring the hottest temperature within an area
- 8.9 Measuring the coldest temperature within an area
- 8.10 Hiding measurement tools
- 8.11 Changing the color palette
- 8.12 Working with color alarms
- 8.13 Changing image mode
- 8.14 Changing the temperature scale mode
- 8.15 Setting the emissivity as a surface property
- 8.16 Setting the emissivity as a custom material
- 8.17 Changing the emissivity as a custom value
- 8.18 Changing the reflected apparent temperature
- 8.19 Changing the distance between the object and the camera
- 8.20 Performing a non-uniformity correction (NUC)
- 8.21 Configuring Wi-Fi
- 8.22 Changing the settings
- 8.23 Updating the camera
- 9 Technical data
- 10 Mechanical drawings
- 11 CE Declaration of conformity
- 12 Cleaning the camera
- 13 Application examples
- 14 About FLIR Systems
- 15 Definitions and laws
- 16 Thermographic measurement techniques
- 17 History of infrared technology
- 18 Theory of thermography
- 19 The measurement formula
- 20 Emissivity tables
Technical data9
Measurement analysis
Isotherm
Above/below/interval
Emissivity correction Variable from 0.1 to 1.0
Emissivity table Emissivity table of predefined materials
Reflected apparent temperature correction Automatic, based on input of reflected
temperature
Set-up
Color palettes Black and white, iron and rainbow
Set-up commands Local adaptation of units, language, date and time
formats
Storage of images
File formats Standard JPEG, 14-bit measurement data
included
Digital camera
Digital camera, resolution 640 × 480
Digital camera, FOV
55° × 43°
Data communication interfaces
Interfaces USB Micro: Data transfer to and from PC and
Mac device
Wi-Fi Peer-to-peer (ad hoc) or infrastructure (network)
Radio
Wi-Fi
• Standard: 802.11 b/g/n
• Frequency range:
◦ 2400–2480 MHz
◦ 5150–5260 MHz
• Max. output power: 15 dBm
Power system
Battery type Rechargeable Li ion battery
Battery voltage 3.6 V
Battery operating time
Approx. 4 hours at +25°C (+77°F) ambient tem-
perature and typical use
Charging system Battery is charged inside the camera or in specific
charger.
Charging time
2.5 hours to 90% capacity in camera. 2 hours in
charger.
Charging temperature 10°C to +45°C (+50°F to +113°F)
Power management Automatic shut-down
AC operation AC adapter, 90–260 VAC input, 5 VDC output to
camera
Environmental data
Operating temperature range –15°C to +50°C (+5°F to +122°F)
Storage temperature range –40°C to +70°C (–40°F to +158°F)
Humidity (operating and storage) IEC 60068-2-30/24 h 95% relative humidity
#T559828; r. AK/40423/40423; en-US
52