4. Push the navigation pad. This displays a dialog box where you can define the settings
for the alarm.
For the Condensation alarm, the following parameters can be set:
Atmospheric temperature: The current atmospheric temperature.
Relative humidity: The current relative humidity.
Relative humidity limit: The relative humidity level at which you want the alarm to
be triggered. A relative humidity of 100% means that water vapor condenses from
the air as liquid water (= dewpoint). A relative humidity of about 70% or above can
cause mold.
For the Insulation alarm, the following parameters can be set:
Indoor temperature: The current indoor temperature.
Outdoor temperature: The current outdoor temperature.
Thermal index: The insulation level (an integer between 0 and 100).
5. Push the navigation pad. This closes the dialog box.