User's Manual
Table Of Contents
- 1 Disclaimers
- 2 Safety information
- 3 Notice to user
- 4 Customer help
- 5 Quick start guide
- 6 Register the camera
- 7 A note about ergonomics
- 8 Camera parts
- 9 Screen elements
- 10 Navigating the menu system
- 11 Handling the camera
- 11.1 Charging the battery
- 11.2 Installing and removing the camera battery
- 11.3 Turning on and turning off the camera
- 11.4 Adjusting the angle of lens
- 11.5 Adjusting the infrared camera focus manually
- 11.6 Autofocusing the infrared camera
- 11.7 Continuous autofocus
- 11.8 Operating the laser distance meter
- 11.9 Measuring areas
- 11.10 Connecting external devices and storage media
- 11.11 Moving files to a computer
- 11.12 Assigning functions to the programmable buttons
- 11.13 Using the camera lamp as a flash
- 11.14 Changing camera lenses
- 11.15 Neck strap
- 11.16 Hand strap
- 12 Saving and working with images
- 13 Working with the image archive
- 14 Achieving a good image
- 15 Working with image modes
- 16 Working with measurement tools
- 17 Working with color alarms and isotherms
- 18 Annotating images
- 19 Programming the camera (time-lapse)
- 20 Recording video clips
- 21 Screening alarm
- 22 Pairing Bluetooth devices
- 23 Configuring Wi-Fi
- 24 Fetching data from external FLIR meters
- 25 Changing settings
- 26 Cleaning the camera
- 27 Technical data
- 27.1 Online field-of-view calculator
- 27.2 Note about technical data
- 27.3 Note about authoritative versions
- 27.4 FLIR T530 24°
- 27.5 FLIR T530 42°
- 27.6 FLIR T530 24° + 14°
- 27.7 FLIR T530 24° + 42°
- 27.8 FLIR T530 24° + 14° & 42°
- 27.9 FLIR T530 42° + 14°
- 27.10 FLIR T540 24°
- 27.11 FLIR T540 42°
- 27.12 FLIR T540 24° + 14°
- 27.13 FLIR T540 24° + 42°
- 27.14 FLIR T540 24° + 14° & 42°
- 27.15 FLIR T540 42° + 14°
- 28 Mechanical drawings
- 29 Application examples
- 30 About FLIR Systems
- 31 Terms, laws, and definitions
- 32 Thermographic measurement techniques
- 33 The secret to a good thermal image
- 34 About calibration
- 34.1 Introduction
- 34.2 Definition—what is calibration?
- 34.3 Camera calibration at FLIR Systems
- 34.4 The differences between a calibration performed by a user and that performed directly at FLIR Systems
- 34.5 Calibration, verification and adjustment
- 34.6 Non-uniformity correction
- 34.7 Thermal image adjustment (thermal tuning)
- 35 History of infrared technology
- 36 Theory of thermography
- 37 The measurement formula
- 38 Emissivity tables
Fetching data from external FLIR
meters
24
24.1 General
You can fetch data from some external FLIR meters that support Bluetooth and merge
this data into the infrared image. When the camera is connected to a FLIR meter via
Bluetooth, the measurement value from the meter is displayed in the result table of the
camera. The FLIR meter value is also added to the information saved in the image file.
In preview mode and when editing an image in the archive, you can add more than one
value from the same FLIR meter. The last added value is displayed below the previous
values. The live value is displayed with a dotted outline.
If the screen display for values is full, it is still possible to add more values from the FLIR
meter. Added values are then indicated by a box with a number that counts up each time
a new value is added.
To find out whether a FLIR meter is supported by the camera, consult the meter
documentation.
24.2 Technical support for external meters
Technical support
Website
http://support.flir.com
E-mail TMsupport@flir.com
Phone 855-499-3662
Repairs repair@flir.com
24.3 Procedure
Note
• Before you can use a FLIR meter with the camera, you need to pair the devices. For
more information, see section 22 Pairing Bluetooth devices, page 85.
• To add more than one FLIR meter value when saving an image, preview mode must
be enabled. Select
(Settings) > Save options and storage > Preview image before
saving = On.
Follow this procedure:
1. Turn on the camera.
2. Turn on the FLIR meter.
#T810253; r. AA/42549/42549; en-US
87