Maintenance Manual

910-0001-00-INS -R05 FLIR Proprietary Information Page 15 of 53
Information contained in this document pertains to a Canadian origin product that is controlled as "dual use" by the Canadian
government. However, when in the United States or possessed by a US person, it may be considered a defense article from the US Government's
perspective. US government authorization may be required for re-transfer to a foreign person. If you have any questions, please contact FLIR's
Global Trade Compliance group at exportquestions@flir.com .
2.2.5 Radar Power Supply
The radar power supply provides 28 VDC to the R1, R2, R3, R3D, R5 and R5D Radar Assemblies. Refer to
Section 3.2 for determining the appropriate power supply capacity required.
2.2.6 Network Infrastructure
The network infrastructure consists of Ethernet switches, Ethernet media converters, wireless Ethernet
transceivers, etc. The network infrastructure provides the physical support for the Device and the
Client networks. Refer to the Configuration Manual for a description of these networks.
2.2.7 Cabling
FLIR Radar Systems provide connectorized cables for sale in standard lengths. Pre-cut cable lengths
vary. You can order cables with connectors at both ends. Please contact your FLIR Sales Representative
for assistance.
3 PLANNING SYSTEM INSTALLATION
Before installing the R1, R2, R3, R3D, R5 and R5D Radar Systems, the following installation parameters
of the R1, R2, R3, R3D, R5 and R5D radar assemblies must be determined:
Final location
Height above ground and tilt angle
Power requirements
System network topology, and network components needed to support this topology
3.1 RADAR ASSEMBLY INSTALLATION
3.1.1 Determining an Optimal Location
The optimal R1, R2, R3, R3D, R5 and R5D Radar Assembly location is determined based on the following
factors:
Unobstructed line of sight to the area under surveillance
Radar height above ground
Proximity to large radar reflectors such as buildings, trucks, aircraft and other large
metallic objects
Operating mode (FastScan or Doppler)
Power and connectivity availability
Line of sight to other R1, R2, R3, R3D, R5 and R5D units