By default, one transmission sector from 300° to 60° is configured. For most deployments is it
recommended to use complete coverage by setting the sector to 0° to 360°. If an assembly causes
some interference with other equipment or, if there are other reasons for changing the transmission
sector(s), use the following steps:
Step 1 Start the Radar Console application in direct mode
Step 2 Logon to the Radar Console. Select the desired radar assembly to configure, and click on the
button.
Step 3 In the Parameters window, Radar Setup group of parameters, and Current, select the start
and stop angles of the desired transmit sector and press enter, as shown in Figure 27. After
entering the start and stop angles, press the FLASH button. The radar assembly will reset.
Figure 27 - Configuring the Radar Assembly Transmission Sectors