6 TROUBLESHOOTING
The following tables cover the Built-In Test (BIT) error codes and their description and solutions for
resolving problems.
Note
In the event that any of these error codes are reported, follow the procedure below.
Step 1 Try re-initializing the system.
Step 2 If the error persists, gather the following information:
Physical installation
Network topology
Software version
Radar serial number
Conditions under which the error occurred
Any relevant application/system logs
Step 3 Contact Customer Support.
Error Code format: <Failure Category> . <Sub-Assembly code> <number>
Failure
Category
Description
0
Host-Equipment Continuity
1
Radar Temperature
2
Radar Transmitter/Receiver Current
3
Radar Transmitter/Receiver Voltage
4
Radar Scan Monitoring
5
Radar RF Signal Monitoring
6
Embedded GPS Communication
7
Radar RF Signal Synchronization
8
Radar Time Synchronization
9
Configuration and Parameters
10
Memory Check (RAM, Flash, etc.)
Table 12 - Radar Failure Category Definition