Quick Connection Guide

427-0089-00-28 Rev 160 June 2020
This document does not contain any export-controlled information.
FC-Series O, FC-Series ID Camera
Quick Connect Guide
Caution!
Except as described in this guide, do not disassemble the FC-Series camera.
Damage to the camera can occur as the result of careless handling or
electrostatic discharge (ESD).
Before installing the FC-Series camera you should read and understand the
following documents which provide details regarding mechanical dimensions
and installation safety.
FLIR FC-Series O/ID Installation and User Guide (427-0089-00-12)
FLIR FC-Series Interconnect Document (427-00XX-YY-41)
Power: Power Over Ethernet Plus (PoE+) or 11 - 32 Vdc or 18 - 32 Vac
Power terminal blocks: wire size from 16 AWG to 20 AWG
Analog Video Cable: BNC-terminated RG-59/U solid-center coax cable
Ethernet Cable: Cat5e or Cat6
Accessory I/O plugs: conductor size 22 - 24 AWG, stranded, 1.6 mm max
diameter including insulation for IDC fast connect. Otherwise, 20 - 24 AWG for
push-in spring connect, strip ends 6 mm. GPIO accessory cable.
FLIR Systems, Inc.
6769 Hollister Avenue
Goleta, CA 93117
USA
Support: https://www.flir.com/support/
Corporate Headquarters
27700 SW Parkway Ave.
Wilsonville, OR 97070
USA