Quick Installation Guide
Table Of Contents
- 1 Quick Install Guide
- 1.1 Check Contents
- 1.2 Select a Location
- 1.3 Connect the Camera
- 1.4 Configure for Networking
- 1.5 Mount the Camera
- 1.6 Connect the Camera
- 1.7 Aim the Camera
- 1.8 Check the Boresight
- 1.9 Configure the Analytics
- 1.10 Attach the Camera to a Supported VMS
- 1.11 Camera Dimensions
- 1.12 Register the Product
- 1.13 Contact Information
427-0102-00-28 Triton FH-Series QIG Rev 110
November 2021
This document does not contain any export-controlled information.
Connection
Description
4
10-pin terminal
block x 2
Connect wires from alarm or audio I/O devices, or from IR LED
illuminators, to the appropriate pins on a ten-pin connector included
in the camera kit. Then, plug the connectors into the terminal blocks.
To use the camera's external IR illumination feature to turn
illuminators on and off, connect them to ALARM OUT 2.
Pin
Connection
Pin
Connection
1
AUDIO IN
1
ALARM IN 1
2
GND
2
GND
3
AUDIO OUT
3
ALARM IN 2
4
GND
4
GND
5
GND
5
ALARM OUT 1 NO
6
RS-485-TX-N
6
ALARM OUT 1 COM
7
RS-485-TX-P
7
ALARM OUT 1 NC
8
RS-485-RX-P
8
ALARM OUT 2 NO
9
RS-485-RX-N
9
ALARM OUT 2 COM
10
GND
10
ALARM OUT 2 NC
5
DC12V (IN)
Connect wires from an external power supply
to the three-pin connector included in the
camera kit. Then, plug the connector into the
terminal block.
Pin
1
2
3
-
NC
+
6
ILLUMINATION
POWER OUT 1
AC24V
Connect wires from illuminators and an external power supply to the
two-pin connectors included in the camera kit. Then, plug the
connectors into the terminal blocks.
·
Do not connect a DC12V power supply to the DC24V
connection.
·
Do not use the DC12V and AC24V / DC24V IN
connections at the same time.
·
The ILLUMINATION POWER OUT 1 + 2 AC24V
connections can supply a maximum 4.2A total to
external illuminators. They must be connected to
equipment with fireproof enclosures. FH-Series cameras
support Raytec Long-Range Infra-Red illuminator models
VAR2-i6-1, VAR2-i6-2, VAR2-i8-1, VAR2-i8-2, and
VAR2-i16-1. For information about which Raytec
illuminator each model supports, see the FLIR Security -
Accessory Guide.
7
POWER INPUT
24V AC / DC
7.2A
8
ILLUMINATION
POWER OUT 2
AC24V
9
Anchor a ground strap to this grounding lug and connect it to the
nearest earth-grounding point.